Operation Manual

en
11
Vertical check
You must create a reference to perform this test. Fasten a plumbline near to
the wall. The laser unit should now be set up in front of this reference mark
(distance Y) and the vertical laser line compared with it.
The discrepancy between the centre of the laser line and the reference mark
should be no greater than 1 mm ( 3/64” ) over a length of 2 m ( 8 ft ).
Checking plumblining
1. Switch the unit on
2. Place the laser so that its down beam is over a reference mark on the floor.
3. Locate the position of the up beam on the ceiling and make a mark.
4. Rotate the laser 180° and realign the down beam over the reference mark
on the floor.
5. Locate the position of the up beam on the ceiling and make a mark.
6.Measure the di erence D between the two marks on the ceiling, which will be
twice the actual error. The di erence may not be greater than: 3 mm in 5 m
(1/8“ in 16‘5“).
Replacing the batteries
Slide the battery cover (4) in the direction of the arrow and insert new
batteries in accordance with the symbols in the battery compartment.
Suitable batteries can also be used.
Technical data
Laser type: Red diode laser, pulsed line-laser,
wavelength 635 nm
Output: < 1 mW, Laser Class 2 to IEC 60825-1:2007
This product compl. with the appl. requ.
of 21CFR, parts 1040.10 and 1040.11.
Self-levelling range*: ca. ± 4,5°
Levelling accuracy :
laser line horizontal*: L1 = ± 0,3 mm/m middle of the laser line
L1 = ± 3/16” over 50
inclination of the laser line : L2 = ± 0,2 mm/m laser line
L2 = ± 1/8” over 50
Up Beam Accuracy*: L3 = ± 0,3 mm/m ± 3/16“ over 50 
Down Beam Accuracy: L4 = ± 0,4 mm/m ± 1/4“ over 50 
Batteries:: 3 x 1,5 V cells Alkaline, Size AA, LR6 LR6
Operating life: Approx. 20 hours (Alkaline)
Operating temperature range : -10 °C to +50 °C / 14°F to +122°F
Storage temperature range: -20 °C to +60 °C / -4°F to +140°F
Subject to technical modi cations.
* When operated within speci ed temperature range
H3
H1
I1
I2
H2
A6
A7
K