Operation Manual
13
ENGLISH
Overload protection tripped.
Remove cause for overload
(water too warm? Pump blocked
by foreign objects?)
Motor hums but does not start:
Pump blocked by foreign object.
Clean pump.
Pump does not pump properly:
Delivery head too high.
Observe max. delivery head (see
"Technical Specifications").
Discharge hose kinked.
Straighten discharge hose.
Discharge hose leaky.
Seal discharge hose, tighten
screw fittings.
Pump runs very noisily:
Pump primes air.
Ensure a sufficient supply of
water.
A
Danger!
Have your power tool serviced by a
qualified repair person using only
identical replacement parts. This will
ensure that the safety of the power
tool is maintained.
Contact your local Metabo representa-
tive if you have Metabo power tools
requiring repairs. See www.metabo.com
for addresses.
You can download a list of spare parts
from www.metabo.com.
All packaging materials are recyclable.
Worn out power tools and accessories
contain considerable amounts of valua
-
ble raw and plastic materials, which can
be recycled.
9. Repairs
10. Environmental Protection
11. Technical Specifications
TBP 4000 M TBP 5000 M
Mains voltage V 230 1 230 1
Frequency Hz 50 50
Rated output W 750 1000
Rated current A 4,0 5,5
Fuse protection min. (time-lag or B-type circuit breaker) A 10 10
Running capacitor F 16,0 16,0
Rated speed min
-1
2800 2800
Pump capacity max. l/h 3800 5000
Delivery head max. m 55 60
Delivery pressure max. bar 5,5 6,0
Immersion depth max. m 20 20
Max. temperature of primed medium °C 35 35
Protection class IP 68 IP 68
Degree of protection I I
Insulation class B B
Materials stainless steel
and
synthetic material
stainless steel
Power cable (HO 7 RN-F) m 22 22
Discharge port (AG=male, IG=female) 1" IG 1" IG
Dimensions (pump casing)
Height
Diameter
mm
mm
920
98
920
98
Impellers 7 8
Weight without cable
with cable
kg
kg
10,5
12,0
10,7
12,2
Max. length of extension cable
at 3 x 1.0 mm
2
lead cross-section
at 3 x 1.5 mm
2
lead cross-section
m
m
30
50
30
50