Installation Guide

© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
31
CLASSIC RIB
®
RESIDENTIAL PANEL INSTALLATION
FIRST PANEL INSTALLED
INSTALLING SECOND EAVE PANEL
STEP
3
STEP
4
INSTALLING SECOND PANEL
STITCH SCREW
RIDGE PANEL
EAVE PANEL
TAPE SEALANT
FASTENER
INSIDE CLOSURE
FASTENER
ANTI-
SYPHON
GROOVE*
1. Apply a row of Tape Sealant across and over the ribs of the rst panel about 3" from panel end.
2. Install the second panel over the rst panel and Tape Sealant with a 6" Endlap. Fasten through both
panels and Tape Sealant into support with appropriate amount of fasteners to meet local building
code. (see fastening pattern on page 6). Fasteners must penetrate sealant.
3. After securing panel at eave, repeat the fastening pattern at the appropriate spacing to meet local
building codes.
1. Place the lapping seam of the second panel on top of previously installed panel so that panel ends
are ush at eave (see below).
2. Fasten through panel, closure, and Tape Sealant into support with appropriate amount of
fasteners to meet local building code. (see fastening pattern on page 6). Fasteners must penetrate
closure and sealant.
3. After securing panel at eave, repeat the fastening pattern at the appropriate spacing to meet local
building codes.
6"
*PANELS WITHOUT AN ANTI-
SYPHON GROOVE REQUIRE TAPE
SEALANT IN THE SIDELAP.