seCTion ProPerTies and general inforMaTion
ALLOWABLE UNIFORM LOADS PSF
(3 or More Equal Spans)
0'-6"
SECTION PROPERTIES
Bottom in Compression
Width
(in.)
Yield
KSI
24" 5026
Ga.
Sxx
In
3
/ft
Ixx
In
4
/ft
Weight
PSF
0.77
Top in Compression
Sxx
In
3
/ft
Ixx
In
4
/ft
0.0025 0.0069 0.0015 0.0054
Outward Uplift Load
1'-0" 1'-6" 2'-0" 2'-6" 3'-0"
101 89 60 34 22 15
24" 5024 1.02 0.0030 0.0089 0.0020 0.0073
101 89 60 34 22 15
1. TheoreticalsectionpropertieshavebeencalculatedperAISI2001.“SpecicationsfortheDesignofCold-formedSteelStructural
Members.”IxxandSxxareeffectivesectionpropertiesfordeectionandbending.
2. AllowableloadiscalculatedinaccordancewithAISI2001specicationsconsideringbending,shear,combinedbendingandshearand
deection.Allowableloadconsidersboth3ormoreequalspanconditions.Allowableloaddoesnotaddresswebcripplingor
fasteners/support connection. Panel weight is not considered.
3. DeectionconsiderationislimitedbyamaximumdeectionratioofL/180ofspan.
4. Allowable loads do not include a 1/3 stress increase in uplift.
12"
1
/
2
"
C
24" Coverage
#9-15x2" Woodscrew
Slope
Substructure
Coverage
Length
Fasteners
Availability
GENERAL INFORMATION
ATTACHMENT DETAIL
FASTENING PATTERNS
The minimum recommended slope for 5V-Crimp roong
panel is 3:12.
*ContactMetalSalesTechnicalServicesforMiami-DadeCountyattachmentrequirements.
#9-15x2" Woodscrew
#9-15x2" Woodscrew
Field of Panel
Ends of Panel
The recommended substrate is
5
/
8
" plywood with a 30
pound felt moisture barrier. To avoid panel distortion use
a properly aligned and uniform substructure.
NOTE: 5V-Crimp roof panels are not recommended for
use over open structural framing.
Minimum factory cut length is 5'-0". Maximum
recommended panel length is 45'-0". Longer panels
require additional consideration in packaging, shipping, and
erection. Please consult Metal Sales for recommendations.
The fastener selection guide should be consulted for
choosing the proper fastener for specic applications.
Quantity and type of fastener must meet necessary loading
and code requirements.
NOTE: All panels are subject to surface distortion due to
improperly applied fasteners. Overdriven fasteners will
cause stress and induce oil canning across the face of the
panel at or near the point of attachment.
Finishes: Acrylic Coated Galvalume
®
and MS Color-
fast45
®
Gauges: 26ga and 24ga
5V-Crimp panels are available in a
1
/
2
" rib height with a
coverage width of 24".