Installation User Manual

© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
7
CLASSIC RIB
®
PANEL INFORMATION
Anti-Siphon Groove
Classic Rib Panel
1
/
4
"-14 x
7
/
8
" Stitch Screw
(for roof only)
#9-15 Woodscrew
1. Theoretical section properties have been calculated per AISI 2007 'North American Specication for the Design of Cold-Formed Steel
Structural Members'. Ixx and Sxx are effective section properties for deection and bending.
2. Allowable load is calculated in accordance with AISI 2007 specications considering bending, shear, combined bending and shear and
deection. Allowable load considers the 3 or more equal spans condition. Allowable load does not address web crippling, fasteners,
support material or load testing. Panel weight is not considered.
3. Deection consideration is limited by a maximum deection ratio of L/180 of span.
4. Allowable loads do not include a 1/3 stress increase for wind.
5. Diaphragm Capacity - 296 plf average Ultimate Shear Strength using the above fastening pattern on 2x supports located 2' on center,
per ASTM E 445.
ALLOWABLE UNIFORM LIVE LOADS, psf
For various fastener spacings
1.5 2’ 2.5’ 3’ 3.5’ 4’ 1.5’ 2’ 2.5’ 3’ 3.5’ 4’
SECTION PROPERTIES
Bottom in Compression
Width
in
Yield
ksi
36 80
36 80
36 50
29
Ga
26
24
Sxx
in
3
/ft
Ixx
in
4
/ft
Weight
psf
0.62
0.79
1.03
Top in Compression
Sxx
in
3
/ft
Ixx
in
4
/ft
Inward
Load
Outward
Load
0.0100 0.0151 0.0053 0.0118 142 81 52 36 27 21 179 103 66 46 34 26
0.0127 0.0192 0.0070 0.0153 185 105 68 47 35 27 227 131 84 59 44 33
0.0163 0.0249 0.0103 0.0208 208 119 77 53 39 30 245 141 91 64 47 36
PANEL LAP DETAIL
SECTION PROPERTIES