TM Residential Roof Systems Vertical Seam & Image II Design Manual
RESIDENTIAL DESIGN GUIDE Important Information The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. All projects should conform to applicable building codes for that particular area. It is recommended to follow all building regulations and standard industry practices.
RESIDENTIAL DESIGN GUIDE 9 Branch Territory Map 8 18 6 17 21 3 11 14 1 4 12 5,10 7 19 20 15 2 13 16 TABLE OF CONTENTS * NOTE: Shaded areas represent regions served by each location. Important Information ..........................................1 Branch Territory Map ...........................................2 Branch Locations .................................................3 Vertical Seam Panel Options ...............................4 Vertical Seam Design Information.................
RESIDENTIAL DESIGN GUIDE Branch Locations 15.) FONTANA BRANCH 14213 Whittram Avenue Fontana, CA 92335 909.829.8618 Phone 800.782.7953 Toll Free 909.829.9083 Fax 16.) ANCHORAGE BRANCH 4637 Old Seward Highway Anchorage, AK 99503 907.646.7663 Phone 866.640.7663 Toll Free 907.646.7664 Fax 1.) DENVER BRANCH 7990 E. I-25 Frontage Road Longmont, CO 80504 303.702.5440 Phone 800.289.7663 Toll Free 800.289.1617 Toll Free Fax 8.) SPOKANE BRANCH East 2727 Trent Avenue Spokane, WA 99202 509.536.6000 Phone 800.572.
Vertical Seam Panels RESIDENTIAL DESIGN GUIDE Factory-Applied Sealant 1-3/4" 1-3/4" with Striations 12",16" oror18" Coverage 12", 16", 18" Coverage Factory-Applied Sealant 1-3/4" 1-3/4" Flat Pan 12", 16", 18" Coverage 12",16" oror18" Coverage 4 Product No.
Vertical Seam Design Information RESIDENTIAL DESIGN GUIDE GENERAL INFORMATION ATTACHMENT DETAIL Slope The minimum recommended slope for the Vertical Seam roof panel is 3:12 over open framing and 1:12 over solid substrate. Clip Factory Applied Sealant Pancake Head Fastener Clips Clip spacing is based upon the spacing of structural framing members and loading requirements.
12" or 16" Coverage Image II Panels RESIDENTIAL DESIGN GUIDE 1"1" 1" Flat Pan with Striations 12" or 16" Coverage Coverage 12" or16"16" Coverage with Minor Ribs Flat Pan 1"1" 1" Coverage 16" 16" Coverage 12" or 16" Coverage 1" 1"1" with Minor Ribs with Minor Ribs Coverage 12" 12" Coverage 16" Coverage No.
Image II Design Information RESIDENTIAL DESIGN GUIDE GENERAL INFORMATION ATTACHMENT DETAIL Slope The minimum recommended slope for the Image II roof panel is 3:12. Woodscrew Substructure Image II Panel Image II is designed to be utilized over a solid substrate. To avoid panel distortion use a properly aligned and uniform substructure. NOTE: Image II roof panels are not recommended for use over open structural framing.
Flashing Profiles RESIDENTIAL DESIGN GUIDE 7" RIDGE/HIP COVER Specify Pitch C 7" 1" Open Hem Product No. Length Gauge Finish 5013141 10'-2" 26 Galvalume (ACG) 50131XX 10'-2" 26 CF45 Painted 51131XX 10'-2" 26 PVDF Painted 5213141 10'-2" 24 Galvalume (ACG) 52131XX 10'-2" 24 PVDF Painted Product No.
Flashing Profiles RESIDENTIAL DESIGN GUIDE RESIDENTIAL PITCH BREAK Specify Pitch 4" C Product No. Length Gauge Finish 5394341 10'-2" 26 Galvalume (ACG) 53943XX 10'-2" 26 CF45 Painted 51143XX 10'-2" 26 PVDF Painted 5294341 10'-2" 24 Galvalume (ACG) 52943XX 10'-2" 24 PVDF Painted Product No.
RESIDENTIAL DESIGN GUIDE FLAT CLEAT (Field Cut to 1" Pieces) 3/4" Flashing Profiles Product No.
Flashing Profiles RESIDENTIAL DESIGN GUIDE RESIDENTIAL RAKEWALL C 6" Open Hem 11/2" Product No. Length Gauge Finish 5012941 10'-2" 26 Galvalume (ACG) 50129XX 10'-2" 26 CF45 Painted 51129XX 10'-2" 26 PVDF Painted 5212941 10'-2" 24 Galvalume (ACG) 52129XX 10'-2" 24 PVDF Painted Flashing Stretch Out = 8-7/8" 13/8" Open Hem RESIDENTIAL W-VALLEY Specify Pitch Open Hem C 10" 70º 7 /8" 1" Product No.
RESIDENTIAL DESIGN GUIDE VERTICAL SEAM Z-CLOSURE 1" 13/4" C Flashing Profiles Product No.
RESIDENTIAL DESIGN GUIDE VERTICAL SEAM CLIP PROFILE VENT PROFILE VENT CLIPS TUBE SEALANT DOUBLE BEAD TAPE SEALANT Accessories Product No. Height Weight/Ea Finish 4923565 1-3/4" 0.15 lbs Galvanized Product No. Panel Profile Length Type 6462118 16" Vertical Seam 100' Notched 6462119 18" Vertical Seam 100' Notched 6441799 12" Image II 100' Notched 6441898 16" Image II 50' Notched 6441899 16" Image II 100' Notched Product No.
RESIDENTIAL DESIGN GUIDE Tools 20" DUAL BAR FOLDER/HEMMER Product No. 6531299 TURBO SHEARS Product No. VERSA HEMMER 6531499 6534599 VERSA BENDER SINGLE Product No. VERSA BENDER DOUBLE STATION 6531599 14 Product No. © Metal Sales Manufacturing Corporation / Subject to change without notice 6/14 Product No.
RESIDENTIAL DESIGN GUIDE POP RIVET PANCAKE HEAD WOOD SCREW TRUSS HEAD WOOD SCREW WOOD SCREW WOOD SCREW XL STITCH STITCH XL METALWOOD SCREW Fasteners Product No. Description WT/250 Finish 8240901 1/8" x 3/16" Stainless Steel .75 lbs Bare 82409XX 1/8" x 3/16" Stainless Steel .75 lbs Painted Product No. Description WT/250 Finish 8243100 #10-12 x 1" PH Wood Screw 1.90 lbs Plated Product No. Description WT/250 Finish 8243300 #8-15 x 1" TH Wood Screw 1.
RESIDENTIAL PRODUCT GUIDE Vertical Seam Eave y Tube Sealant on top of the male rib 6" up from the end of the panel u Hem flat pan of panel to accept Offset Cleat x w z v Part Description C Product No. Length Installation Information Wrap cardboard around panel hem when crimping closed to the Offset Cleat. 50022XX 26 Gauge 10'-2" Offset Cleat 5506499 26 Gauge 10'-2" 3 Pancake Head Wood Screw 8243100 1" 1 every 6" fastened through the Offset Cleat and Double Bead Tape Sealant.
RESIDENTIAL PRODUCT GUIDE Vertical Seam Extended Eave x Tube Sealant on top of the male rib 6" up from the end of the panel Hem flat of panel to accept Extended Eave Flashing v u w u Part Description C Product No. Length Installation Information Wrap cardboard around panel hem when crimping closed to the Extended Eave. Residential Extended Eave 50134XX 26 Gauge 10'-2" 2 Pancake Head Wood Screw 8243100 1" Fasten 6'-0" o.c. to hold Extended Eave Flashing in place.
Vertical Seam Residential Valley RESIDENTIAL DESIGN GUIDE Tube Sealant on top of the male rib 6" up from the end of the panel u x w 6" v z { Bend the flat pan of panel around to accept offset cleat y Part Description Product No. Residential W-Valley 50136XX 26 Gauge Offset Cleat 3 Length Installation Information 10'-2" Always install W-Valley Flashing working from eave up slope.
RESIDENTIAL PRODUCT GUIDE Turn panel up 1-3/4" along rake edge Vertical Seam Residential Rake Field telescope notch 3" u x w y 2" v z Vertical Seam Residential Rake Flashing Lap Detail Part Description Product No. Length Installation Information C 1 Vertical Seam Residential Rake 50127XX 26 Gauge 10'-2" Rake Flashing hooked over the panel edge. Attach to the Rake Cleat. Pinch hem closed along the entire rake edge.
Rakewall w/ Counter Flashing RESIDENTIAL DESIGN GUIDE Description 20 Installation Information Fill the space between the Counter Flashing and the wall. 1 Tube Sealant 2 Fastener by Others 3 Residential Counter Flashing 4 Fastener by Others 5 Residential Rakewall 6 Tube Sealant Apply a continuous bead of Tube Sealant to the slip pocket. 7 Tube Sealant Apply a continuous bead of Tube Sealant to the inside corner of the panel prior to attaching the flashing.
Rakewall w/ Counter & Receiver RESIDENTIAL DESIGN GUIDE Detail for Installation of Siding Prior to Panels Description Installation Information 1 Residential Counter Flashing Receiver 2 Fastener by Others 3 Pop Rivet Fasten Receiver to the Counter Flashing 12" o.c. 4 Residential Counter Flashing Flat Slide into open hem of Counter Flashing Receiver 5 Residential Rakewall 6 Tube Sealant Apply a continuous bead of Tube Sealant to the slip pocket.
RESIDENTIAL PRODUCT GUIDE Vertical Seam Rakewall u Residential Rakewall Flashing Lap Detail v w 2" Vertical Seam Panel turn up 1-3/8" 3" Field telescope notch Part C 1 Slip Pocket 2 3 22 Description Product No. Residential Rakewall 50129XX 26 Gauge Tube Sealant 6403200 64032XX Apply a continuous bead of Tube Sealant to the slip pocket. 6403200 64032XX Apply a continuous bead of Tube Sealant to the inside corner of the panel prior to attaching the flashing.
Vertical Seam Hip / Non-Vented Ridge RESIDENTIAL PRODUCT GUIDE u Turn up flat pan of each panel 45° at the ridge/hip condition x w v Section A-A Part C 7" Description Product No. 7" Ridge/Hip Cover 50131XX 26 Gauge 1 C Length Installation Information 10'-2" Slide Ridge/Hip Cover over top flange of Z-Closures. 1" end tabs on Z-Closure.
RESIDENTIAL PRODUCT GUIDE Vertical Seam Ridge/Hip Notch Detail w u v Description 1 Ridge/Hip Cover 2 Pop Rivet 3 Tube Sealant 24 Installation Information Telescope notch each piece 3" at high side and fasten to the adjacent Ridge/Hip Flashing with a Pop Rivet on each side. 2 Pop Rivets per notched tab, attaching the flashings. Apply two rows of Tube Sealant between the two lapped flashings.
RESIDENTIAL PRODUCT GUIDE Vertical Seam Hip End Cap Detail w A u u v v A x y z { z { 1/2"-1" miter, depending on slope Description Installation Information 1 Ridge/Hip Cover Open hems of the Hip Flashing slide onto 1" top flanges of Z-Closure. Fold 1" hems over top flashings of Vertical Seam end cap. Attach high side of flashing as shown on page 24. 2 Vertical Seam Z-Closure Z-Closures over continuous Double Bead Tape Sealant.
RESIDENTIAL PRODUCT GUIDE Vertical Seam Pitch Break Fastener by Others u u x v Part 1 2 3 4 26 C C w Description Product No. Residential Pitch Break 53943XX 26 Gauge 10'-2" Open hem hooks onto Z-Closure. Vertical Seam Z-Closure 55702XX 26 Gauge 10'-2" 1" end tabs on Z-Closure. Pancake Head Wood Screw 8243100 1" Double Bead Tape Sealant 6403899 Length Installation Information 25' 4 required at every Z-Closure fastening through the Double Bead Tape Sealant.
RESIDENTIAL PRODUCT GUIDE Vertical Seam Vented Peak u u z { w x { y x RESIDENTIAL CLEAT OPTIONAL INSTALLATION Part Description Product No.
RESIDENTIAL PRODUCT GUIDE Vertical Seam Peak u B u z x w A y y y v OPTIONAL CLEAT INSTALLATION Part Description Product No. Length Installation Information Vertical Seam Residential Peak 50133XX 26 Gauge 10'-2" Peak flashing face can be attached directly to substrate or hooked on Residential Cleat. Vertical Seam Z-Closure 55702XX 26 Gauge 10'-2" 1" end tabs on Z-Closure. Residential Cleat 5013599 26 Gauge 10'-2" Optional concealed fastener installation.
RESIDENTIAL DESIGN GUIDE Peak Flashing Lap Details Peak Flashing Lap - Front View A 2 Rows of Tube Sealant Front of Residential Peak Residential Cleat Pop Rivet Telescope Notch 3" Peak Flashing Lap - Top View Z-Closure Fastener Top of Residential Peak Open Hem on Peak Flashing over Z-Closure B 2 Rows of Tube Sealant Z-Closure Panel Rib Pop Rivet Panel Rib Open Hem on Peak Flashing over Z-Closure Telescope Notch 3" © Metal Sales Manufacturing Corporation / Subject to change without notice 6/
RESIDENTIAL PRODUCT GUIDE Image II Eave y Tube Sealant on top of the male rib 6" up from eave u Bend flat pan of panel around to accept offset cleat x w z v Part Description C Product No. Length Installation Information Wrap cardboard around panel hem when crimping closed to the Offset Cleat. 50022XX 26 Gauge 10'-2" Offset Cleat 5506499 26 Gauge 10'-2" Offset Cleat should be installed so that the edge aligns with the fascia board.
RESIDENTIAL PRODUCT GUIDE Image II Extended Eave x Tube Sealant on top of the male rib 6" up from eave Bend flat pan of panel around to accept Extended Eave Flashing v u w u Part Description C Product No. Length Installation Information Wrap cardboard around panel hem when crimping closed to the Extended Eave. Residential Extended Eave 50134XX 26 Gauge 10'-2" 2 1" Pancake Head Wood Screw 8243100 1" Fasten 6'-0" o.c. to hold Extended Eave Flashing in place.
RESIDENTIAL PRODUCT GUIDE Image II Residential Valley Tube Sealant on top of the male rib 6" up from eave u x w 6" v z { Bend the flat pan of panel around to accept offset cleat y Part Description Product No. Residential W-Valley 50136XX 26 Gauge Offset Cleat 3 Length Installation Information 10'-2" Always install W-Valley Flashing working from eave up slope.
RESIDENTIAL PRODUCT GUIDE Turn panel up 1" along rake edge Image II Residential Rake Field telescope notch 3" u x w y 2" v z Image II Residential Rake Flashing Lap Detail Part Description Product No. Length Installation Information C 1 Image II Residential Rake 50126XX 26 Gauge 10'-2" Rake Flashing hooked over the panel edge. Attach to the Rake Cleat. Pinch hem closed along the entire rake edge.
Rakewall w/ Counter Flashing RESIDENTIAL DESIGN GUIDE Description 34 Installation Information Fill the space between the Counter Flashing and the wall. 1 Tube Sealant 2 Fastener by Others 3 Residential Counter Flashing 4 Fastener by Others 5 Residential Rakewall 6 Tube Sealant Apply a continuous bead of Tube Sealant to the slip pocket. 7 Tube Sealant Apply a continuous bead of Tube Sealant to the inside corner of the panel prior to attaching the flashing.
Rakewall w/ Counter & Receiver RESIDENTIAL DESIGN GUIDE Detail for Installation of Siding Prior to Panels Description Installation Information 1 Residential Counter Flashing Receiver 2 Fastener by Others 3 Pop Rivet Fasten Receiver to the Counter Flashing 12" o.c. 4 Residential Counter Flashing Flat Slide into open hem of Counter Flashing Receiver 5 Residential Rakewall 6 Tube Sealant Apply a continuous bead of Tube Sealant to the slip pocket.
RESIDENTIAL PRODUCT GUIDE Image II Rakewall u Residential Rakewall Flashing Lap Detail v w 2" Image II Panel turn up 1-3/8" 3" Field telescope notch Part 1 2 3 36 C Description Product No. Residential Rakewall 50129XX 26 Gauge Tube Sealant 6403200 64032XX Apply a continuous bead of Tube Sealant to the slip pocket. 6403200 64032XX Apply a continuous bead of Tube Sealant to the inside corner of the panel prior to attaching the flashing.
Image II Hip/Non-Vented Ridge RESIDENTIAL PRODUCT GUIDE u Turn up flat pan of each panel 45° at the ridge/hip condition x w v Section A-A Part C 7" Description Product No. 7" Ridge/Hip Cover 50131XX 26 Gauge 1 C Length Installation Information 10'-2" Slide Ridge/Hip Cover over top flange of Z-Closures. 1" end tabs on Z-Closure.
RESIDENTIAL PRODUCT GUIDE Image II Hip/Ridge Notch Detail w u v Description 1 Ridge/Hip Cover 2 Pop Rivet 3 Tube Sealant 38 Installation Information Telescope notch each piece 3" at high side and fasten to the adjacent Ridge/Hip Flashing with a Pop Rivet on each side. 2 Pop Rivets per notched tab, attaching the flashings. Apply two rows of Tube Sealant between the two lapped flashings.
RESIDENTIAL PRODUCT GUIDE Image II Hip End Cap Detail w A u u v v A x y z { z { 1/2"-1" miter, depending on slope Description Installation Information 1 Ridge/Hip Cover Open hems of the Hip Flashing slide onto 1" top flanges of Z-Closure. Fold 1" hems over top flashings of Vertical Seam end cap. Attach high side of flashing as shown on page 38. 2 Image II Z-Closure Z-Closures over continuous Double Bead Tape Sealant.
RESIDENTIAL PRODUCT GUIDE Image II Pitch Break Fastener by Others u u x v Part 1 2 3 4 40 C C w Description Product No. Residential Pitch Break 53943XX 26 Gauge 10'-2" Open hem hooks onto Z-Closure. Image II Z-Closure 55603XX 26 Gauge 10'-2" 1" end tabs on Z-Closure Pancake Head Wood Screw 8243100 1" Double Bead Tape Sealant 6403899 Length Installation Information 25'-0" 4 required at every Z-Closure fastening through the Double Bead Tape Sealant.
RESIDENTIAL PRODUCT GUIDE Image II Vented Peak u u z { w x { y x RESIDENTIAL CLEAT OPTIONAL INSTALLATION Part Description Product No.
RESIDENTIAL PRODUCT GUIDE Image II Peak u B u z x w A y y y v OPTIONAL CLEAT INSTALLATION Part Description Product No. Length Installation Information Residential Peak 50134XX 26 Gauge 10'-2" Peak flashing face can be attached directly to substrate or hooked on Residential Cleat. Image II Z-Closure 55603XX 26 Gauge 10'-2" 1" tabs required on Z-Closure. Residential Cleat 5013599 26 Gauge 10'-2" Optional concealed fastener installation.
RESIDENTIAL DESIGN GUIDE Peak Flashing Lap Details Peak Flashing Lap - Front View A 2 Rows of Tube Sealant Front of Residential Peak Residential Cleat Pop Rivet Telescope Notch 3" Peak Flashing Lap - Top View Z-Closure Fastener below Top of Residential Peak Open Hem on Peak Flashing over Z-Closure B 2 Rows of Tube Sealant Z-Closure Panel Rib Pop Rivet Panel Rib Open Hem on Peak Flashing over Z-Closure Telescope Notch 3" © Metal Sales Manufacturing Corporation / Subject to change without not
RESIDENTIAL PRODUCT GUIDE Skylight/Chimney Detail SKYLIGHT INSTALLATION Part LOW SIDE OF SKYLIGHT/CHIMNEY C 44 C CHIMNEY INSTALLATION Description Product No. Residential Pitch Break 53943XX 26 Gauge Vertical Seam Z-Closure 55702XX 26 Gauge Image II Z-Closure 55603XX 26 Gauge Pancake Head Wood Screw 8243100 Double Bead Tape Sealant 6403899 Tube Sealant 6403200 64032XX Length Installation Information 10'-2" Cut 2'-0" longer than the width of the Skylight or Chimney.
RESIDENTIAL DESIGN GUIDE RIGHT AND LEFT SIDE Part Skylight/Chimney Detail cont. Description Residential Rakewall C Product No. 50129XX 26 Gauge Length Installation Information 10'-2" Slide Residential Rakewall over the vertical panel edge. Part Tube Sealant 6403200 64032XX Description Product No. Apply a continuous bead of Tube Sealant to the slip pocket and inside corner of panel (see rakewall detail).
RESIDENTIAL DESIGN GUIDE Care and Maintenance Though factory applied pre-painted finishes are very durable and will last many years, eventually it may be desirable to thoroughly clean or repaint them. Dirt pickup may cause apparent discoloration of the paint when it has been exposed in some dirt laded atmospheres for long periods of time. In areas of strong sunlight, slight chalking may cause some change in appearance.
RESIDENTIAL DESIGN GUIDE Notes © Metal Sales Manufacturing Corporation / Subject to change without notice 6/14 47
RESIDENTIAL DESIGN GUIDE 48 Notes © Metal Sales Manufacturing Corporation / Subject to change without notice 6/14