seCTion ProPerTies and general informaTion
24" Coverage
Factory Applied Sealant
5"
3"
19"
C
1. TheoreticalsectionpropertieshavebeencalculatedperAISI2001“SpecicationfortheDesignofCold-formedSteelStructuralMembers.”IxxandSxxare
effectivesectionpropertiesfordeectionandbending.
2. AllowableloadiscalculatedinaccordancewithAISI2001specicationsconsideringbending,shear,combinedbendingandshear,deection,andASTM1592
testing.Allowableloadconsiderstheworstcaseof3and4equalspanconditions.Allowableloaddoesnotaddresswebcripplingor
fasteners/supportconnectionandpanelweightisnotconsidered.
3. DeectionconsiderationislimitedbyamaximumdeectionratioofL/180ofspan.
4. Allowableloadsdonotincludea1/3stressincreaseinuplift.
*LoadsdeterminedusingtheS-5!Clamp.
ALLOWABLE UNIFORM LIVE LOADS PSF
(3 or More Equal Spans)
2.5’ 3’ 3.5’ 4’ 4.5’ 5’ 2.5’ 3’ 3.5’ 4’ 4.5’ 5’
SECTION PROPERTIES
Bottom in Compression
Width
(in.)
Yield
KSI
24” 50
24” 50
24
Ga.
22
Sxx
In
3
/ft
Ixx
In
4
/ft
Weight
PSF
1.14
1.49
Top in Compression
Sxx
In
3
/ft
Ixx
In
4
/ft
0.3070 0.1271 0.1250 0.0819 196 150 118 96 79 66 26 25 23 21 20 18
0.4045 0.1673 0.1740 0.1113 275 210 165 133 109 90 33 31 28 26 24 22
0.3070 0.1271 0.1250 0.0819 196 150 118 96 79 66 97 86 76 65 55
Inward (Gravity / Deection)
Load
Outward Uplift (Stress)
Load
24” 5024* 1.14
Clip
Snap-Loc 24
®
Panel
Factory Applied Sealant
Slope
Substructure
Clips
Coverage
Length
Fasteners
Availability
GENERAL INFORMATION
ATTACHMENT DETAIL
PANEL CLIP
The minimum recommended slope for the Snap-Loc 24 roof
panel is 1/4:12.
Snap-Loc 24 is designed to be utilized over open structural
framing or a solid substrate.
Clip spacing is based upon the spacing of structural framing
members and loading requirements.
Snap-Loc 24 panels are available in a 3" seam height with
a 24" width coverage.
Minimum factory cut length is 5'-0". Maximum
recommended panel length is 45'-0". Longer panels
require additional consideration in packaging, shipping, and
erection. Please consult Metal Sales for recommendations.
The fastener selection guide should be consulted for
choosing the proper fastener for specic applications.
Quantity and type of fastener must meet necessary loading
and code requirements.
NOTE: All panels are subject to surface distortion due to
improperly applied fasteners. Overdriven fasteners will
cause stress and induce oil canning across the face of the
panel at or near the point of attachment.
Finishes: Acrylic Coated Galvalume
®
and
PVDF (Kynar 500).
Gauges: 24 ga and 22 ga
Base
Base
Clip
Clip
1
1
/
8
"
Tab
Tab
Factory Applied
Sealant
Clip Fastener
S-5! Clamp (Optional)