INSTALLATION OF VALLEY FLASHING
VALLEY
1. Begin by installing a sheet of 36" wide Ice and Water Shield in the valley so that it extends up
each side of the valley 18".
2. Place Valley flashing over the Ice and Water Shield starting at the eave and working upward
towards the ridge.
3. If two or more Valley flashings are required, lap the flashing over the previously installed flashing
by a minimum of 12" placing a bead of Tube Sealant between the flashings along the edge
where they lap.
4. Place Woodscrew XL fasteners at 2'-0" o.c. 1" from the top edge of the Valley flashing on
each side of the valley.
ICE AND WATER SHIELD
WOODSCREW XL
EAVE OR GUTTER FLASHING
VALLEY FLASHING