Installation Manual

STILE
28
© Metal Sales Manufacturing Corporation/ Subject to change without notice
INSTALLATION OF PANEL (CONT)
1. All Stile panels meeting the valley must be field cut at an angle so that the panels stop 3" from
the center of the valley.
2. When starting Stile panel near a valley, tilt the right side of the panel
1
/16" lower than the left
side. This is required to keep the panel thickness from accumulating at the eave (see page 24).
3. A foam Universal Closure or Stile Closure is placed between the previously installed Valley
flashing and Stile panel. Tube Sealant is used with the closure to prevent moisture and
debris from getting under the panels.
4. Woodscrew XL fasteners are required along the edge of the cut panel just below each step.
5. Place a fastener at every other valley and every third step throughout the panel.
6. Optional Valley Cover is installed over the Stile panel at the valley. Fasten the Valley Cover to the
rib of the Stile panel with a
1
/8" Pop Rivet on both sides of the Valley Cover at 1'-0" o.c.
1. All panels meeting the hip must be field cut at an angle so that the Stile panel fits into the
previously installed Stile C-Closure (see page 22). When Formed Ridge flashing is used, Stile
C-Closure is not required.
2. When starting Stile panel near a hip, tilt the right side of the panel
1
/16" lower than the left
side. This is required to keep the panel thickness from accumulating at the eave (see page 24).
3. Woodscrew XL fasteners are required along the edge of the cut panel just below each step.
4. Place a fastener at every other valley and every third step throughout the panel.
PANEL AT VALLEY CONDITION
ICE AND WATER SHIELD
WOODSCREW XL
UNIVERSAL CLOSURE
VALLEY FLASHING
WOODSCREW XL
STILE PANEL BEVEL CUT IN FIELD
PANEL AT HIP CONDITION