Installation Manual

STILE
33
© Metal Sales Manufacturing Corporation/ Subject to change without notice
INSTALLATION OF RUBBER ROOF JACK
1 On vent pipe penetrations, the roofing felt should fit very tightly around the penetration.
2. Take the appropriate measurements for the vent location and mark them on the Stile panel. Cut
the Stile panels to fit the opening properly.
3. Once the Stile panels are applied, flash the vent pipe with a Rubber Roof Jack or similar pipe
flashing.
4. Apply Tube Sealant between the panel and the base of the Rubber Roof Jack as well as the area
around the top where the boot meets the pipe.
5. Attach the base of the Rubber Roof Jack to the panel using
1
/4 - 14 x
7
/8" Stitch fasteners.
RUBBER ROOF JACK
STILE PANEL
WOODSCREW XL
RUBBER ROOF JACK
(APPLY SEALANT AROUND BASE)
#2 (1
3
/4" TO 3" O.D. PIPE)
#3 (3" TO 6" O.D. PIPE)
#6 (6" TO 9" O.D. PIPE)
#8 (7" TO 13" O.D. PIPE)