Installation Manual

STILE
34
© Metal Sales Manufacturing Corporation/ Subject to change without notice
INSTALLATION OF STILE ROOF VENT
STILE ROOF VENT
The Stile Roof Vent allows compliance with many new venting regulations and is suitable for new
construction and reroofing. The Stile Roof Vent offers 31 square inches of ventilation area and
complies with Uniform Building Code requirements. In all cases the installer should conform to
applicable building codes for that area. The base of the Stile Roof Vent is formed with the same
profile as the Stile panel for ease of installation.
STILE PANEL
STILE ROOF VENT
WOODSCREW XL
SEALANT
(USED AROUND PERIMETER OF VENT BASE)
USED AS AN ATTIC VENT
1. It is recommend that the Stile Roof Vent location be determined after the Stile panel is installed.
2. Select location and mark where the vent base rests on the Stile panel.
3. Measure, mark, and cut a 9" wide and 16" long rectangular vent opening in the Stile panel.
4. Measure, mark, and cut the 5" x 8" opening in the plywood decking.
5. Apply two continuous beads of Tube Sealant on the panel
1
/2" from the marks made for the base. This
should form a rectangle slightly smaller than the vent.
6. Fit the Stile Roof Vent back in place and press it down firmly so that the Tube Sealant forms a
weathertight seal. Fasten the Stile Roof Vent to the Stile panel using ten Woodscrew XL fasteners.
The fasteners should be placed 1" from the sides and ends of the Stile Roof Vent .