ITEMS REQUIRED
(Purchase separately)
• Phillips screwdriver
• Flat head screwdriver
• Wire Cutters
• Hammer
• Safety glasses
• Wire Strippers
• Ladder
IMPORTANT SAFETY INSTRUCTIONS
• Read and follow these instructions.
• Heed all warnings, including below warnings AND those included on product.
• Save these instructions and warnings.
• Risk of fire/electric shock.
• Ground fixture to avoid potential electric shock.
• Turn off the power at fuse or circuit breaker box before installation and maintenance.
• Edges may cut. Handle with care.
CAUTION
• Connect fixture to a 120/277 volt, 60 Hz power source. Any other connection voids
the warranty.
• Fixture should be installed by persons with experience wiring or by a qualified
electrician. The electrical system, and the method of electrically connecting the
fixture to it, must be in accordance with the National Electrical Code and local
building codes.
• This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
ENGLISH
A. Fixture housing assembly
Assemblage du boîtier du luminaire
Unidad de alojamiento de la luminaria
LCRL Series
WARNING
receiver is connected.
- Consult the dealer or an experienced radio
/TV technician for help.
WARNING: FCC Regulations state that any
unauthorized changes or modifications to this
equipment not expressly approved by the
manufacturer could void the user’s authorization
to operate this equipment.
SAVE THESE INSTRUCTIONS.
Installation
Fixture Installation/Wiring
1. Remove product from packaging material.
Do not lift fixture by one end or pull on the end
plates in any way. Luminaire should be handled by
both side rails.
2. Install the luminaire into the ceiling T-grid system.
Ensure that the luminaire sits snuggly in T-grid
system (Figure 2).
3. For EQ clip accessory kit, order CZ2-EQCLIP-U-PK
(4 in bag)
4. Grid lock tabs are provided on end plates. Fold out
90º as shown. When required, fasten EQ Clip
Accessory Kit to luminaire end plates with screws
from the kit to secure luminaire to T-grid system.
Remove electrical access plate and remove
necessary knockouts from access plate for
attachment of electrical supply cable (Figure 3).
5. Make necessary wiring connections to driver AC
line input. A Linear Disconnect is provided to speed
installation (Figure 4).
6. Replace electrical access plate and snap securely
into place. If required, install optional screw to lock
the access plate closed.
NOTE: Fixture is compatible with 0-10V low voltage
dimmer. When installing switch follow your dimmer
instructions for wiring to low-voltage purple (Dim +)
and grey (Dim -) leads.
Standard Access Plate Installation
Step 1: To insert access plate, rotate until leading end
is inside the wireway (Figure 3).
Step 2: Fold into horizontal position and slide forward
into locking position.
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Electrical Enclosure
EQ Clip (x4)
Grid Lock Tab
Step 1
Step 2
Leading
End
Linear Disconnect
Black
Black
White
White