Specification Sheet

Specifications and
dimensions subject to
change without notice.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
24AC LED 2’ X 4’
SAMPLE NUMBER: 2 4AC-LD5-55-UNV-L835-CD1-U
44=4400 Lumens
55=5500 Lumens
Shielding
[Blank]=Standard Lens
SQP=Lens with Square
Pattern Insert
RDP=Lens with Round
Pattern Insert
Lamp Type
LD5=LED 5.0
NOTES:
(1)
Products also available in non-US voltages and frequencies for international markets.
(2)
With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the
desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire unde
r emergency operation available.
(3)
Air versions are not designed for continuous row
mount
applications. Air version is vented but does not meet air handling requirements.
(4)
347V emergency option not available.
(5)
3100 and 3600 lumen options not available with Step-dim driver and wiyh Fifth Light drivers
(5LTD and 5LTHD).
(6)
Used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided by others). GTR2 and ETR2 options include 2 relays on fixtures with dimming drivers.
ETRD option only requires one relay when used on a dimming fixture. Must specify voltage as 120V or 277V when ordering these de
vices.
(7)
DesignLights Consortium® Qualified and classified for both DLC Standard
and DLC Premium, refer to www.designlights.org for details.
Stock Lumen Outputs
MTO Lumen Outputs
31=3100 Lumens
(5)
36=3600 Lumens
39=3900 Lumens
48=4800 Lumens
63=6300 Lumens
68=6800 Lumens
73=7300 Lumens
Integrated Sensing and Control System Options
NOTES:
Integrated options must be used in conjuction with the associated system and may not be compatible with other options or accessories. Please refer to the following:
(A)
Consult WaveLinx system pages for
additional details and compatibility.
(B)
Consult LumaWatt Pro system pages for additional details and compatibility.
(C)
Consult DLVP system pages for additional details and compatibility.
(D)
Consult SVPD series system
pages for additional details and compatibility.
(E)
Consult Fifth Light system pages for additional details and compatibility.
(F)
Consult Marketplace Options - Lutron system pages for additional details and compatibility.
Compatible only with driver series shown, and may require two or more drivers. Requires field commissioning to operate or dim.
Contact Lutron at www.lutron.com.
Series
(7)
24AC=2' x 4' Accord
Series
Rating
[Blank]=
Standard
ATW-SW4=
Chicago
Rated
Type
[Blank]=Standard
A=Air(vented)
(3)
Voltage
(1)
UNV=Universal Voltage 120-277
347V=347 Volt
(4)
48V=48 Volt Low-voltage (Class 2)
(C)
Options
Emergency
EL7W=7-watt, 120V-277V emergency
battery pack installed
(2)
EL14W=14-watt 120V-277V emergency
battery pack installed
(2)
ELV7W=7-watt, DLVP-compatible low voltage
emergency battery pack installed
(C)
ELV14W=14-watt DLVP-compatible low voltage
emergency battery pack installed
(C)
GTR2=Bodine Generator Transfer Relay
(6)
ETR2=Iota Emergency Transfer Relay
(6)
ETRD=Iota Emergency Transfer Relay with
dimming control
(6)
Lamps
L830=3000K
L835=3500K
L840=4000K
Flex
A3/8-4/18GDIM=3/8" Flex with 0-10V Dimming Leads
Multiple other configurations available. See below for details.
Driver Type
CD=0-10V Dimming Driver
(1%-100% Dimming)
SR=Sensor-ready Dimming Driver
for LWIPD1 option
(1%-100% Dimming)
(B)
5LTD=Fifth Light DALI Driver
(10%-100% Dimming)
(E)
5LTHD=Fifth Light Dimming Driver
(1%-100% Dimming)
(5), (E)
LV1=DLVP Dimming Driver
(0%-100% Dimming)
(C)
SD=Step Dimming Driver
(50% or 100% Dimming)
(5)
LH=Lutron HiLume (LDE1 series) 1%-100% EcoSystem Driver
with Soft-on Fade to Black dimming
(F)
L5=Lutron 5 Series (LDE5-Series) 5%-100% EcoSystem Driver
(F)
LU=Lutron HiLume (L3D series) 1%-100% EcoSystem/3-wire Driver
(F)
Number of Drivers
1=1 Driver
2=2 Drivers
Packaging
U=Unit Pack
PALC=Job
Pack, in carton
Integrated Sensing Systems
SWPD1=WaveLinx Wireless Integrated Sensor
(A)
LWIPD1=LumaWatt Pro Wireless Integrated Sensor
(B)
LWTPD1=LumaWatt Pro Wireless Tile-mount Sensor
(B)
SLVPD1=DLVP Low-voltage Integrated Sensor
(C)
SVPD1=0-10V Stand-alone Integrated Sensor
(D)
ACCESSORIES
T3A END E.Q. BRACKET PARTS BAG
DF-24-W=2' x 4' Drywall Frame Kit
SK-24-WS=2' x 4' Shallow Surface Mount Kit
SK-24-WT=2' x 4' Tall Surface Mount Kit
DF10P-C =Decorator Dimmer, 0-10V
SF10P- =Decorator Dimmer, 0-10V
ORDERING INFORMATION
Catalog No. Wt.
24AC-LD5-44 21 lbs.
24AC-LD5-55 21 lbs.
SHIPPING DATA
stalled and pre-wired to driver, fitted to luminaire housing access plate with 90° enclosed FMC
Factory installed dimming option 3/8” flexible metal conduit with 2-#18 power and ground wires and 2-#18 UL-listed jacketed 0-10V +/- control wires. Meets UL 66, 83, 1479, 1569, 1581, 2556.
ormerly J-C-30B); all applicable OSHA and HUD Requirements. UL Classified 1-, 2-, and 3-hour
formation.
PS519157EN
May 7, 2018 10:00 AM