Instructions / Assembly

2
7. Locate power supply wires from the junction box and pull them through the knockout that
has been removed on the main channel body so that the wires and disconnect are inside
the housing channel (Fig. 5).
8. Attach main housing channel to ceiling or wall using #8 or larger diameter wood screws
plus #10 flat washer for stud mount or 3/16” diameter or larger toggle bolt plus #10 flat
washer for drywall mounting. The spacing for mounting brackets is 37-3/16” for 4’ fixture
or 14 9/16” for 2’ fixture. (Fig. 6 & 7).
Note: 2’ fixture mounting hole pattern is not symmetric.
9. Fully reconnect the quick disconnect by pushing the mating ends together (Fig. 8).
10. Locate the channel cover with LEDs and provided lead wires to make connections to the
driver output wires and ground wire. To properly engage wires, firmly push wire leads
into the orange in-line connector attached to the driver output leads. Connect the black
lead on the cover with the black lead on the driver. Then, connect the red lead on the
cover with the red lead on the driver. Lastly, connect the green lead on the cover with the
green ground lead on the housing channel. For fixtures with 2 drivers connect the second
set of black and red wires to the Channel cover with LED’s. Black to black and red to red
(Fig. 9A, 9B & 9C).
Note: For dimming see Installing Dimmer Instruction Section.
11. Tuck all the excess supply wire, orange inline connectors, and the quick disconnect back
into the main channel housing.
12. Mechanically attach the Channel cover with LED’s back to the housing channel by sliding
the Channel cover with LED’s holes onto the locking tabs on the main housing channel
(Fig. 10) Remove protective film from the lens.
13. Optional: Attach decorative end caps by placing the end cap’s locking tabs over the ends
of the fixture and sliding towards the center of the fixture until both the locking tabs snap
into end cap holes on main housing (Fig. 11A & 11B).
Note: Decorative end caps cannot be placed between two fixtures which have been
row mounted together. For row mounting decorative end caps can only be placed on
far ends of fixture.
ROW MOUNTING
1. For row mounting locate the metal end plate at the end of the fixture of the main channel
body which you plan to remove. Remove the endplate screw from the metal endplate
(Fig. 12). Repeat for adjacent fixture.
2. Squeeze the main channel housing to release the locking tabs on the metal end plate
and remove the metal end plate from main channel housing (Fig. 13). Repeat for
adjacent fixture.
3. Using one of the metal end plates which you just removed break away the row mounting
tab by bending the end plate. A few maximum bends may be required to completely
break away the tab (Fig. 14A).
Fig. 5
Fig. 6
Fig. 7
Fig. 9B
Fig. 9A
Fig. 11A
Fig. 8
Fig. 10
Fig. 11B
Fig. 13
Fig. 14A
Fig. 12
Joist Mount
Drywall
Detached
Use Large
Hole Only
Locking
Tabs
End Cap
Hole
Bending End Plate
Endplate
Screw
Fig. 9C
Red
Red
Black
Black
Green
Green
Note: Mounting hole pattern
not symmetric
4 ft. Striplight
2 ft. Striplight
37-3/16 in. (944 mm)
8 13/16 in.
(223.50 mm)
5 3/4 in.
(146.50 mm)
14 9/16 in. (370 mm)