Installation Instructions
Instruction Manual/Instrucciones/Directives
Questions?/¿Preguntas?/Questions ? 1-800-334-6871 www.eaton.com/lighting
1
INSTALLATION INSTRUCTIONS
1. Turn off the power at the main fuse/breaker box.
Carefully open carton, remove fixture from carton.
2. Remove channel cover by squeezing in three places
by locking tabs in fixture housing. (Fig 1)
3. Remove appropriate knockout(s) for power
supply wiring. To remove, simply place a flathead
screwdriver on the knockout and strike it sharply
with a hammer (Fig. 2). The slug may then be
removed with pliers.
4. To install the four T-bar clips, first locate the 3/16”
holes in each end plate. Mount and fasten the four
supplied T-bar clips and the four 10-32 x 1/2 inch
screws into housing as shown. (Fig. 3).
5. Carefully lift fixture into ceiling opening. Locate
the fixture to the center of the opening, spread the
tabs on the T-bar clips (so the middle tab no longer
passes through the center), and then lower unit
the grid T-bar clips set down on top of the ceiling
T-bar. When you are done locating the fixture where
to install it, pull carefully down on the fixture to
snap the T-clips over the ceiling grid T-bar. Now,
it should look like (Fig. 4) after you have mounted
the fixture. To comply with National Electrical code
the T-bar clips must be fastened to the ceiling grid
T-Bar as shown. (Fig. 4).
6. Guide wires from the junction box
through the knockout on the fixture (Fig. 5).
ITEMS REQUIRED
(Purchase separately)
• Wire Connectors
• Phillips screwdriver
• Flat head screwdriver
• Pliers
• Hammer
• Safety glasses
• Ladder
IMPORTANT SAFETY INSTRUCTIONS
When using product, basic precautions should always be followed, including the following:
• Read and follow these instructions.
• Heed all warnings, including below warnings AND those included on product.
• Save these instructions and warnings.
• Risk of fire/electric shock.
• Ground fixture to avoid potential electric shock.
• Turn off the power at fuse or circuit breaker box before installation and maintenance.
• Edges may cut. Handle with care.
Notice: Lamps contain mercury, dispose according to local, state, or federal laws.
For more information, visit: www.lamprecycle.org.
CAUTION
• Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids
the warranty.
• Fixture should be installed by persons with experience in household wiring or by a
qualified electrician. The electrical system, and the method of electrically connecting
the fixture to it, must be in accordance with the National Electrical Code and local
building codes.
ENGLISH
A. Fixture housing
Alojamiento del accesorio
Boîtier de l’appareil d’éclairage
B. Channel Cover
Cubierta del canal
Protecteur du canal
PACKAGING CONTENTS/CONTENIDO DEL PAQUETE
GL217R (2 ft)
GL232R (4 ft)
GL432R (4 ft)
WARNING
Fig. 2
A
Fig. 3
A
Wires
C. (4) 10-32 x .5 Screw
(4) tornillos de 10-32 x 0,5
(4) Vis 10-32 x 0,5
D. (4) 10-32 Nut
(4) tuercas de 10-32
(4) Écrous 10-32
E. (4) Clips
(4) ganchos
(4) Pinces
Fig. 1
A
Fig. 4
A
Fig. 5
A