Hardware manual

72
Enter Setup
Metapace S-2 Hardware Manual
1) Read this label above to specify the inter-function delay.
2) Read the “
Decimal Value” label on page 192 for the desired inter-function delay
(millisecond).
3) Read the “Validate” label on the same page to complete this setting.
2.5.9 ACK/NAK TIMEOUT
By default, the scanner sends data to the host without waiting for an ACK/NAK response
before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If
no response within the specified period of time, the scanner will attempt to send the
same data three more times. If all the attempts fail without any notification, data loss
will occur.
1) Read the label above to specify the time interval for the scanner to send data and
wait for a response from the host.
2) Read the “
Decimal Value” label on page 192. For example, read “1” and “0” for the
scanner to automatically shut down after being idle for 1 second.
3) Read the “Validate” label on the same page to complete this setting.
ACK/NAK Error Beep
Note: We suggest enabling the error beep so that you will be notified of such data loss
and have the scanner re-read data.
ACK/NAK Time
-
O
ut after … (*0 ~ 99)
Enable Error Beep
*
Disable Error Beep