DESCRIPTION OF THE DEVICE:
Features:
Innovative DJ-scanner with rotating gobos
7 different, dichroic color filters and white
Rainbow-effect with adjustable speed in both directions
Gobowheel with 7 rotating gobos, open and blackout
Strobe-effect with adjustable speed (1-10 flashes/sec.) via shutter
DMX-controlled operation or stand alone operation with Master/Slave-
function
Sound-controlled via built-in microphone
Fuzzy-Sound-Control: program continues automatically during periods
without music or bass-beat
Control-Board with 4-digit display
Digital DMX focus
For MSD/HSD 250, MSD 250/2 or MSD/HSD 200 lamp
DMX-control via every standard DMX-controller
11 DMX-control channels required
DANGER TO LIFE:
- Only install the lamp with the device switched off. And not plugged into power
- Always unplug power from mains before attempting any service.
- For the installation, you need one MSD 250/2 GY-9.5 lamp.
- The lamp must only be changed when wearing appropriate protective clothing (protection
glasses, protection gloves, helmet with sight, leather apron).
INSTALLATION
Installing/Replacing the lamp Procedure:
CAUTION!
- The lamp has to be replaced when it is damaged or deformed due to the heat!
- The lamp life given by the manufacturer must never be exceeded. This is why you need to
take notes on the operational time of the lamp and replace the lamp in time.
- Keep exchanged lamp in a protective container and remove accordingly.
- During the operation, the lamp reaches temperatures of up to 600° C.
- Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10
minutes).
- During the installation do not touch the glass-bulbs barehanded!
- Please follow the lamp manufacturer's notes!
- Do not install lamps with a higher wattage! Lamps with a higher wattage generate
temperatures the device was not designed for.
- Damages caused by non-observance are not subject to warranty.
Step 1: Unscrew the fixation screws X, Y of the lamp system and carefully remove it from the
housing.
Step 2: If replacing the lamp, remove the old lamp from the lamp holder.
Step 3: Insert the lamp into the lamp holder.
Step 4: Replace the lamp system in the housing and tighten the fixation screws.
Step 5: Adjust the lamp as described under lamp adjustment.
Do not operate this device with opened cover!