Operations Manual

OPERATIONS 4-40
O&M of the MCC-545B PACKET DATA RADIO
12/2000
MCC-545B COMMANDS
COMMAND DESCRIPTION PARAMETERS RANGE
*ASSIGN
{,function,port,protocol
{,timeout}}
NOTE
function, port and protocol
information for ports 0, 1,
2 are stored in EEPROM;
this information for port 3
and all timeout information
is stored in BBU RAM.
Control allocation of user interface functions among
physical device channels. When no parameters are
entered, displays I/O configurations. Port definitions are
as follows:
Front Panel
Port Connector
0 OPERATOR PORT
1 DATA PORT
2 AUXILIARY PORT
3 DIAGNOSTICS PORT (Internal)
NOTE
It is possible to “lose control” of the 545B software by
assigning control functions to ports with no devices
attached or by turning off control functions. For
example, if you turn off the Operator Port
(ASSIGN,MNT,OFF), you will not be able to enter
commands or view printouts from the 545B. You must
open the 545B and press the Reset button on the
microprocessor board to re-enable the Operator Port.
function = user
interface function
port = physical
device channel
protocol = link
level protocol
timeout in
seconds
MNT, POS, MSG,
ALT, DTA, C&S,
0-2, OFF
APCL5, ASCII,
CR10X,
DATALITE, ENAV,
FWS, GPS, GYRO,
IDA, IHS, MSC,
PHAROS, PKT,
RTCM, TM8T
0 – 32767
*BASE{,nnn,nnn} Set display range of Master Station IDs reserved for use
as Base Stations
nnn = Master
Station ID
OFF = no Bases
2 – 245
BINS
Print link distribution statistics
BOOT
Cold start of Station software. All volatile memory is
lost.