Operations Manual

OPERATIONS 4-51
O&M of the MCC-545B PACKET DATA RADIO
12/2000
If device – Remote:
Normal operation
†*ID{,nnn,mmm{,mode}
{,INIT}}
NOTE
Remote and Master IDs are
kept in EEPROM and
mode is kept in BBU
RAM.
Set 545B’s assigned Master Station ID to number “nnn”.
When no parameters are given, current ID is displayed.
When system is already initialized, you must enter the
INIT parameter to change ID. INIT gives “OK” to save
configuration and reboot unit with new ID. ID changes
are automatically saved with the entire configuration in
EEPROM. mode” parameter (if used) specifies initial
connectivity with specified Master. PREF means
Remote considers connectivity established. AUTO
means no connectivity established. FIXED (Default)
means connect only with specified Master.
NOTE
If command does not change the ID or Master Station,
the SAVE and reboot are not performed.
nnn = Remote ID
mmm = Master
ID
mode = PREF,
AUTO or
FIXED
256 – 4095
1 – 245
†ID,mode Change " mode" as discussed above without affecting ID;
no reboot performed.
mode = PREF,
AUTO or FIXED
If device = Master:
*ID{,nnn{,INIT}}
Set 545B’s assigned Master Station ID to number “nnn”.
When no parameters are given, current ID is displayed.
When system is already initialized, you must enter the
INIT parameter to change ID. INIT gives “OK” to save
configuration and reboot unit with new ID. ID changes
are automatically saved with the entire configuration in
EEPROM.
CAUTION
If you enter INIT, you will lose all current message
information.
nnn = assigned
Master ID
1 – 245