FNIRSI-C1 User Manual (V0.
目录 0.0 version and updates...............................................................5 1.0 Overiew...........................................................................5 2.0 pay attention to safety matters...................................................5 3.0 Performance description...........................................................6 3.0.1 Interface.....................................................................6 3.0.2 Human-computer interaction.......................................
9.0.4 Apple 2.4A acceleration......................................................21 10.0 setting menu....................................................................22 10.1 Settings menu -> General......................................................22 10.1.1 Setting menu -> General -> Display brightness.............................22 10.1.2 Settings menu->General->Standby brightness................................22 10.1.3 Settings menu->General->Standby time......................................
0.0 version and updates As the instrument has many functions and frequent software and hardware updates, the manual may be updated at any time, please be aware. Please get the latest update information on the official website. 1.0 Overiew The C1 TYPE-C tester is a high-reliability, high-safety USB voltage and current detection meter and a mobile communication terminal fast charging trigger. It has a 1.3-inch TFT LCD display with 240x240 ultra-high pixels.
3.0 Performance description 3.0.1 Interface 1 Input monitoring port: TYPE-C, 24-PIN male; 2 Output monitoring port: TYPE-C, 24-PIN female socket; 3 PC connection port: Micro-USB, 5-PIN female socket. 3.0.2 Human-computer interaction 1 1.3 inch TFT-LCD screen; 2 Press button x 3. 3.0.3 Voltage and current 1 The highest six-digit display of voltage, current and power, the highest resolution is 0.
6 Supports a maximum of 24 hours for a limited time trigger, and automatically closes the trigger when the time is reached 3.0.5 Wire identification 1 The internal resistance measurement of the wire rod by the differential pressure method; 2 E-Marker cable chip reading. 3.0.5 Miscellaneous 1 Start-up running time record; 2 Onboard temperature measurement; 3 Gravity sensor, automatically switch the display direction, the whole interface supports 4 direction switching; 4 PD monitoring; 5 Apple 2.
5.0 Technical Specifications Accuracy: ±(a%(‰) reading + number of words) Index Range Resolution Accuracy Monitorvoltage 4~24V 0.00001V ±(0.2‰+2) Monitorcurrent 0~6.5A 0.00001A ±(0.5‰+2) Monitor power Loadequivalent 0~130W 0.00001W ±(0.5‰+2) 0~9999.9Ω 0.0001Ω ±(0.5‰+2) 0~3.3V 0.001V ±(1.0%+2) Equipment ℃ 1℃ ±(1.2%+3) temperature ℉ 1℉ ±(1.2%+4) capacity 0~9999.99Ah 0.00001Ah energy used Cable internal 0~9999.99Wh 0.00001Wh 0~9999.9Ω 0.
6.0 Main Page Except for special instructions, left and right buttons switch pages/menus, OK button and click to confirm, OK button and long press to cancel/return. 6.0.1 Concise Page Description Only 4 key parameters of voltage, current, power and load equivalent internal resistance are displayed, → indicates the direction of current. This page can change the display direction.
Instructions (1) Long press the left button: enter the setting menu. (2) Click the OK button: switch to 6-bit resolution. (3) Long press the OK button: when the setting menu -> general -> gravity direction recognition is off, switch the screen direction. 6.0.
(3) Long press the OK button: prompt to restart the calculation of the minimum, maximum, and average values of voltage, current, and power. (4) Long press the right button: enter the offline curve observation page (please see the follow-up instructions). 6.0.
(1) Long press the left button: prompt to enter the fast charge trigger module, if a certain protocol has been triggered, it will prompt to release (2) Click the OK button: start/stop the trigger timing. (3) Long press the middle button: prompt to clear and trigger timing. (4) Long press the right button: enter the charging tool menu (please see the following instructions). 6.0.
Instructions (1) Long press the left button: time base subtraction. (2) Click the OK button: start/pause drawing the curve. (Except in mode 3, it will prompt whether to clear the curve). (3) Long press OK key: switch mode. (4) Long press the right button: time base plus. 7.0 Expansion of recording function 7.0.1 Energy Statistics List Description In the record page (6.0.2) long press the left button to enter.
7.0.2 Offline curve observation page Description Click OK to prompt to clear the record curve. 8.0 Quick charge protocol trigger and detection menu Description On the (6.0.3) fast charge recognition page, long press the left button and confirm to enter. This meter supports QC2.0/QC3.0, HuaWei FCP/SCP, Samsung AFC trigger, PD2.0/3.0 trigger.
must be performed carefully, and it is forbidden to connect to equipment that cannot withstand high voltage. During the use of this function, the author will not be responsible for the loss caused by misoperation. 8.0.1 Automatic detection of fast charge protocol In this mode, the meter tries to trigger various protocols in turn, and displays the test results on the screen. Red means not supported, and green means supported. During the test, it is forbidden to connect to any equipment at the back end.
In QC2.0 trigger mode, use the left and right keys to select the trigger voltage, and long press the OK key to return. 8.0.3 QC3.0 trigger In QC3.0 trigger mode, use the left and right keys to decrease/increase the trigger voltage, and long press the OK key to return. Press the left/right keys to quickly decrease/increase the voltage. 8.0.4 Huawei FCP trigger The operation mode is the same as QC2.0 trigger. 8.0.
The operation mode is the same as QC3.0 trigger. 8.0.6 Samsung AFC Trigger The operation mode is the same as QC2.0 trigger. 8.0.7 PD protocol trigger Take the picture as an example. The picture shows a charger sending a message with a total of 6 gears, among which gears 1, 2, 3, 4, and 5 are fixed voltage gears, and gear 6 is adjustable voltage gear (PPS). When the dot on the left is on Gear, you can switch the gear by pressing the left and right keys.
and right keys (left Decrease right plus), decrease/increase the voltage. 9.0 Charging tool On the (6.0.3) fast charge recognition page, long-press the right button to enter the charging tool menu. The functions are: 1 PD listener. 2 Read the E-Marker cable. 3 wire resistance measurement. 4 Apple 2.4A acceleration. 9.0.1 PD Listener When using a PD monitor, use a power supply not greater than 16V (usually 5V) and a Micro-USB cable to connect to the PC connection terminal, provide external power.
Click the middle button to switch to the "View Detailed Communication Process" page, as shown in the figure above. In the left column, you can select the message to be viewed by the left/key, such as: Now select the message with 0x1882 REQ <-. It is the message number. In this instrument, the larger the message number, the newer the message. 0x1882 is the message header. REQ is the message type, which means that this is a request (Request) message.
9.0.2 Read E-Marker cable E-Marker cable refers to a cable with an E-Marker chip in the Type-C interface. If the interface does not contain an E-Marker chip, the packet from the PD charging head cannot exceed 3A current, and only the E-Marker cable can be used to trigger the PD According to the agreement, the current can exceed 3A. When using the PD monitor, please use the PC communication port for power supply.
comparisons by themselves. 9.0.3 Wire resistance measurement page Description C1 uses the differential pressure method to measure the internal resistance of the cable, which needs to be used with a constant current load. Instructions Click the OK button: use the current voltage and current value as the reference value. Measurement procedure Connection method: charger + C1 + constant current load (the current is adjusted to about 0.5-1A), and record the reference value.
10.0 setting menu Description In the setting menu, left and right buttons can select menu options, click OK to enter/confirm the current options, long press OK to return/cancel/exit the current options/menu. 10.1 Settings menu -> General Set up some general system configurations. 10.1.1 Setting menu -> General -> Display brightness Set the screen brightness, the adjustable range is 1-20 levels. 10.1.
10.1.5 Setting menu->General->Temperature symbol Optional on-board temperature display as ℃/℉. 10.1.6 Settings menu -> General -> System language Currently only Chinese/English is supported. Due to the character size problem, English will be displayed in the Chinese system, which is a normal phenomenon. 10.1.7 Settings menu -> General -> Current change wake up Set the wake-up current. When the current change exceeds the wake-up current, the meter changes from the standby state to the normal working state.
and time statistics are performed, and the setting range is 0-5A. 10.2.3 Settings menu->Record->Energy statistics time When set to None, there is no time limit until the statistics reach the maximum value. After the time is set, the statistics will automatically stop when the statistics time reaches the set value. 10.2.7 Settings menu->Record->Clear all records Clear all recorded data, including offline curves and energy statistics. 10.3 Settings menu -> trigger Trigger related configuration. 10.3.
2 When the meter is off, press the "OK" button fisrt.Then connect the USB data cable to the "PC online port".And it will display the connected, device model, and device firmware version. 3 Click “System”, In the location of the file, import the firmware version you want to upgrade. 4 Click “Refresh icon”,START to start the firmware upgrade. After the upgrade is complete, the watch will automatically restart and enter the main interface. 12.
5 Q: Enter the PD to monitor a black screen? A: Entering the PD monitor will turn off the CC pull-down, so it is recommended to use an external power supply. 6 Q: PD monitoring fails and there is no data? A: Switch to the page of "View detailed communication process", and then long press the left button to clear the data buffer area, and then trigger the monitoring.