User Manual
Table Of Contents
- 0.0 version and updates
- 1.0 Overiew
- 2.0 pay attention to safety matters
- 3.0 Performance description
- 4.0 Appearance structure
- 5.0 Technical Specifications
- 6.0 Main Page
- 7.0 Expansion of recording function
- 8.0 Quick charge protocol trigger and detection menu
- 9.0 Charging tool
- 10.0 setting menu
- 10.1 Settings menu -> General
- 10.1.1 Setting menu -> General -> Display brightness
- 10.1.2 Settings menu->General->Standby brightness
- 10.1.3 Settings menu->General->Standby time
- 10.1.4 Settings menu->General->Data transmission
- 10.1.5 Setting menu->General->Temperature symbol
- 10.1.6 Settings menu -> General -> System language
- 10.1.7 Settings menu -> General -> Current change wake up
- 10.1.8 Settings menu->General->Bluetooth switch
- 10.1.9 Settings menu -> General -> Gravity direction recognition
- 10.1.10 Settings menu->General->Startup page
- 10.1.11 Settings menu->General->Restore factory settings
- 10.2 Settings menu -> record
- 10.3 Settings menu -> trigger
- 10.4 Settings menu -> system
- 10.1 Settings menu -> General
- 11.0 Upgrade firmware instructions (NOTEļ¼The previous FNB38 and FNB48 use the FNIRSI USB Meter upgrade tool.FNIRSI-C1 uses FNIRSI UsbMeter Computer Software to upgrade the firmware now.)
- 12.0 Frequently Asked Questions
Instructions
(1) Long press the left button: enter the setting menu.
(2) Click the OK button: switch to 6-bit resolution.
(3) Long press the OK button: when the setting menu -> general -> gravity direction
recognition is off, switch the screen direction.
6.0.2 Record page
Description
The top row of data from left to right is the boot record time and the onboard
temperature respectively;
The uppercase data on the left is voltage, current, and power from top to bottom;
The curve and progress bar on the right are the remaining storage capacity of the
voltage and current curves;
The groups in the lower left corner are the currently selected statistical group
number, current group statistical time, capacity, and energy;
From top to bottom on the right are the minimum group, maximum group, and
average group during the observation period. Can distinguish voltage, current, and
power according to the unit;
There is a progress bar at the bottom, which is the remaining capacity of the offline
curve. The color display indicates that it is recording, and the gray color indicates that
it is not recording.
Instructions
(1) Long press the left button: switch to the capacity/power consumption list (please
see the following instructions).
(2) Click the OK button: start/stop the voltage and current curve recording. It cannot
be started when the recording time is 0.
10