9.0.3 Wire resistance measurement page
Description
C1 uses the differential pressure method to measure the internal resistance of the
cable, which needs to be used with a constant current load.
Instructions
Click the OK button: use the current voltage and current value as the reference value.
Measurement procedure
(1) Connection method: charger + C1 + constant current load (the current is
adjusted to about 0.5-1A), and record the reference value.
(2) Connection method: charger + cable + C1 + constant current load (the current is
adjusted to about 0.5-1A, and it needs to be followed
The current when recording the reference value is similar), the system automatically
calculates the internal resistance of the cable.
9.0.4 Apple 2.4A acceleration
The Apple device can only charge at 5V-2.4A when it detects that the charging
head D+ and D- are 2.7V. This function sets D+ and D- to 2.7V.