User Manual
Table Of Contents
- 0.0 version and updates
- 1.0 Overiew
- 2.0 pay attention to safety matters
- 3.0 Performance description
- 4.0 Appearance structure
- 5.0 Technical Specifications
- 6.0 Main Page
- 7.0 Expansion of recording function
- 8.0 Quick charge protocol trigger and detection menu
- 9.0 Charging tool
- 10.0 setting menu
- 10.1 Settings menu -> General
- 10.1.1 Setting menu -> General -> Display brightness
- 10.1.2 Settings menu->General->Standby brightness
- 10.1.3 Settings menu->General->Standby time
- 10.1.4 Settings menu->General->Data transmission
- 10.1.5 Setting menu->General->Temperature symbol
- 10.1.6 Settings menu -> General -> System language
- 10.1.7 Settings menu -> General -> Current change wake up
- 10.1.8 Settings menu->General->Bluetooth switch
- 10.1.9 Settings menu -> General -> Gravity direction recognition
- 10.1.10 Settings menu->General->Startup page
- 10.1.11 Settings menu->General->Restore factory settings
- 10.2 Settings menu -> record
- 10.3 Settings menu -> trigger
- 10.4 Settings menu -> system
- 10.1 Settings menu -> General
- 11.0 Upgrade firmware instructions (NOTE:The previous FNB38 and FNB48 use the FNIRSI USB Meter upgrade tool.FNIRSI-C1 uses FNIRSI UsbMeter Computer Software to upgrade the firmware now.)
- 12.0 Frequently Asked Questions
10.1.5 Setting menu->General->Temperature symbol
Optional on-board temperature display as ℃/℉.
10.1.6 Settings menu -> General -> System language
Currently only Chinese/English is supported. Due to the character size problem,
English will be displayed in the Chinese system, which is a normal phenomenon.
10.1.7 Settings menu -> General -> Current change wake up
Set the wake-up current. When the current change exceeds the wake-up current,
the meter changes from the standby state to the normal working state. When set to 0,
the function is turned off。
10.1.8 Settings menu->General->Bluetooth switch
After closing, Bluetooth data transmission is not possible.
10.1.9 Settings menu -> General -> Gravity direction recognition
When opened, the page direction is automatically switched, after closing, the
page reverse cannot be switched automatically, but you can switch the page direction
by long pressing the OK button on the (6.0.1) concise page.
10.1.10 Settings menu->General->Startup page
Turn on/off the boot page.
10.1.11 Settings menu->General->Restore factory settings
Restore all settings except recorded data.
10.2 Settings menu -> record
Set the configuration required for logging data.
10.2.1 Setting menu->Record->Curve record time
Set the recording time of the voltage and current curve, the maximum is 9 hours,
set to no time without recording. Each time you change the configuration, the curve
will be cleared to 0.
10.2.2 Setting menu->Record->Statistical current threshold
When the current is greater than or equal to the threshold, the capacity, energy,
23