Installation Manual Toilet Partitions, Dressing Compartments & Shower Stalls Metpar Corp 95 State Street, Westbury, New York, USA, 11590 Tel: 516-333-2600 Fax: 516-333-2618 Internet: http://www.Metpar.com E-mail: Service@Metpar.
• • • • • • • • • • • • • • • • • Table of Contents Stop! Before you begin. Suggested tools. Metpar tips.
Metpar tips… 1. Plan ahead… coordinate all of the materials and hardware for each specific layout. Study your layout drawings and evaluate any special conditions that may require custom size materials, unique hardware or special tools. 2. When you determine the centerline dimensions, refer to the stall depths shown on your layout drawings. For Powder Shield, Stainless Steel and Plastic Laminate pilasters, the centerline is 5/8” less than the stall depth. Solid Phenolic pilasters are 3/8” less. 3.
STEP 1 - Layout A. Mark the centerline of each stile location from the back wall. The centerline of the stile is 5/8” less than the overall dimension shown. Phenolic = 3/8” less. Measure out at each end of overall distance from first stall to last in line. B. Mark the centerline of all top and bottom wall brackets. Adjust if possible to locate in mortar joints.
A. B. C. D. E. A. B. C. D. E. A. B. C. D. E. F. G. H. I. STEP 4A - Attach Stile FP500 Place plastic anchors into the floor holes. Over each floor anchor place these items in the following order; one (1) shoe clip and one (1) bracket. Fasten into anchor with #12 x 2 ½” screw. Place stile over L-brackets and push panel into Ubrackets up to screw heads. Fasten one #14 x 5/8” sheet metal screw through each L-bracket. Plumb stile, place wedge at top rear between panel and wall. Fasten U-brackets to panel.
STEP 5 - Securing Stiles to Panels A. Stiles must be both plumb and level. Headrail may be used as an aid in this process by temporarily setting them in position (DO NOT fasten it at this time). B. Plumb stile and adjust elevation. Fasten stile to panel using sheet metal screws. C. By adjusting stile L-brackets on FP500, the proper door opening and stile elevation can be attained and set in position by tightening screws. A. B. C. D. E.
A. B. C. D. STEP 8 - Care and Maintenance All surfaces must be kept clean with water and a mild soap solution. Water left on units for extended periods will damage surface. The finish must be wiped dry following cleaning. In high humidity areas, the rooms must be properly ventilated. For maximum protection, periodic applications of good quality car wax will be beneficial for Powder Shield materials. STEP 9 - Need Help? A. A. In the unlikely event that you need further help, you have several resources.
Metpar Corp 95 State Street, Westbury, New York, USA, 11590 Tel: 516-333-2600 Fax: 516-333-2618 Internet: http://www.Metpar.com E-mail: Service@Metpar.com “Installation Manual.