Technical Manual

smarter locking
The content of this document is subject
To change without notice
Page 6
5. COMPONENTS
Electronic Lock RFID ISO SE
Base, strike and front cover
Connection plates
Cabling
6. LOCK POSITION
The lock position has to be identified before the process of wiring. General recommendation is that
the lock should be positioned near to the handle, so the users are operating the locks as directly
as possible. Position may thus vary due to the locker construction, vertical position, etc. The screws
are not supplied since they vary in size and type for different locker constructions and materials.
7. WIRING
Electronic Lock RFID is connected to the connection plate which is part of a Metra EasyWire
Network main line, by six-wire flat cable. For main line connection a three-wire cable is used. The
lock, uncut wires, connectors and connection plates are supplied separately for adjustability to
different situations (wire - lengths), easier process of wiring during installation and later
maintenance. Different types of connection plates are available to suit different locker model. First
identify the position of the locks and corresponding controller (up to 16 locks to one controller).
Find the most suitable way for the wires from the controller to its locks and install the cables. Be
sure to leave cable long enough to be connected to the lock before mounting it (approx. +5 cm).