Product Info
Table Of Contents
- 1.SUMMARY OF STANDARDS AND RESULTS
- 2.GENERAL INFORMATION
- 3.POWER LINE CONDUCTED EMISSION TEST
- 4.RADIATED EMISSION TEST
- 5.CONDUCTED SPURIOUS EMISSIONS
- 6.BAND EDGE COMPLIANCE TEST
- 7.6dB Bandwidth Test
- 8.OUTPUT POWER TEST
- 9.POWER SPECTRAL DENSITY TEST
- 10.ANTENNA REQUIREMENT
Standard-Tech Co., Ltd. Testing Center.
Standard-Tech Co., Ltd. Testing Center. Page
12
of
35
(calibrated bilog antenna) is used as receiving antenna for frequency 30MHz~1000MHz, and
the Horm antenna is used as receiving antenna for frequency above 1GHz. Both horizontal
and vertical polarization of the antenna is set on Test. In order to find the maximum emission
levels, all of the interface cables must be manipulated according to ANSI C63.10-2013 on
radiated emission Test.
The bandwidth of the EMI test receiver (R&S ESR7) is set at 120kHz for frequency range
from 30MHz to 1000 MHz.
The bandwidth of the Spectrum’s VBW is set at 3MHz and RBW is set at 1MHz for peak
emissions measurement above 1GHz and 1MHz RBW, 10Hz VBW for average emissions
measure above 1GHz
4.4.Radiated Emission Test Results
PASS.
Note 1: Final Level= Receiver Read level + Antenna Factor + Cable Loss – Preamplifier
Factor
Note 2: The emissions (9kHz~30MHz) not reported for there is no emission be found.
Note 3: The emission levels of other frequencies(test frequency bang is above 1GHz) are
very lower than the limit and not show in test report.