Product Info
Table Of Contents
- 1.SUMMARY OF STANDARDS AND RESULTS
- 2.GENERAL INFORMATION
- 3.POWER LINE CONDUCTED EMISSION TEST
- 4.RADIATED EMISSION TEST
- 5.CONDUCTED SPURIOUS EMISSIONS
- 6.BAND EDGE COMPLIANCE TEST
- 7.6dB Bandwidth Test
- 8.OUTPUT POWER TEST
- 9.POWER SPECTRAL DENSITY TEST
- 10.ANTENNA REQUIREMENT
Standard-Tech Co., Ltd. Testing Center.
Standard-Tech Co., Ltd. Testing Center. Page
9
of
35
3. POWER LINE CONDUCTED EMISSION TEST
3.1.Block Diagram of Test Setup
3.2.Power Line Conducted Emission Test Limits
Frequency
Maximum RF Line Voltage
Quasi-Peak Level
dB(V)
Average Level
dB(V)
150kHz
~
500kHz
66 ~ 56*
56 ~ 46*
500kHz
~
5MHz
56
46
5MHz
~
30MHz
60
50
Notes: 1. * Decreasing linearly with logarithm of frequency.
2. The lower limit shall apply at the transition frequencies.
3.3.Test Procedure
The EUT was placed on a non-metallic table, 80cm above the ground plane. The EUT Power
Via PC connected to the power mains through a line impedance stabilization network
(V-LISN). This provides a 50 ohm coupling impedance for the EUT (Please refer the block
diagram of the test setup and photographs). The AC line are checked to find out the
maximum conducted emission. In order to find the maximum emission levels, the relative
positions of equipment and all of the interface cables shall be changed according to ANSI
C63.10: 2013 on Conducted Emission Test.
The bandwidth of test receiver (R & S ESR7) is set at 9kHz.
The frequency range from 150kHz to 30MHz is checked.
3.4.Power Line Conducted Emission Test Result
N/A
Note 1: The product is powered by DC 12V and is shipped without an adapter, so the
conduction is exempt from testing