Owner's Manual

Electrical Specifications
14
AC AMPS
Range Resolution Accuracy Notes
20.00mA 10μA
200.0mA 100μA
±(1.5% of
reading
+ 5 digits)
Overload Protection: Fuse
315mA/250V
Input Voltage Drop: <
0.2V.
BATTERY TEST (LEDs)
When the voltage of the battery being tested is lower than 10%
of its rated voltage, the red LED will not
light.
Range
Resolution
Load
Current
Accuracy
Notes
1.5V 0.001V
10mA
(approx.)
Green LED: 1.30V
±0.075V and up.
Yellow LED: 0.94V
±0.075V to 1.29V
±0.075V.
Red LED:
0.15V±0.075V
to 0.93V±0.075V
6V 0.01V
100mA
(approx.)
Green LED: 5.22V
±0.3V and up.
Yellow LED: 3.76V
±0.3V to 5.21V±0.3V.
Red LED: 0.6V±0.3V
to 3.75V±0.3V
9V 0.01V
10mA
(approx.)
Green LED: 7.83V
±0.45V and up.
Yellow LED: 5.64V
±0.45V to
7.82V±0.45V.
Red LED: 0.9V±0.45V
to 5.63V±0.45V
12V 0.01V
200mA
(approx.)
±(5% of
reading
+5 digits)
Green LED: 10.44V
±0.6V and up.
Yellow LED: 7.52V
±0.6V to 10.43V±0.6V.
Red LED: 1.2V±0.6V
to 7.51V±0.6V