Operation Manual
MI 3309 BT DeltaGT Autotest sequences
63
Reading a Code autotest sequence (with barcode scanner, RFID reader/writer or
manually)
Connect barcode scanner or RFID reader/writer to the instrument RS232 / PS2 connector
first.
Figure 6.24: Connection of the barcode scanner and RFID reader/writer
Set RS 232 communication port using Communication function in Setup menu. Select
Code Autotest in Main menu. The latest received or set autotest sequence name and its
code is displayed. A new autotest sequence (received from the barcode scanner or RFID
reader/writer) will be accepted by the instrument (refer to Appendix for available autotest
sequences and its codes). A successful receive of the barcode or RFID tag is confirmed by
two short confirmation beeps.
Figure 6.25: Code autotest menu
The autotest sequence and its code can also be set manually.
Keys:
/
Manually selects autotest sequence by setting its code.
TEST
Starts selected autotest sequence. Refer to chapter 6.5 Carrying out
autotest sequences (Code, Simple and Custom).
ESC
Returns to Main menu.
Reading appliance ID number with barcode scanner or RFID reader/writer
When the instrument is in the Save results menu, appliance ID can be scanned from a
barcode label with the barcode reader or can be read from RFID tag with the RFID
reader/writer. A successful receive of the barcode or RFID tag is confirmed by two short
confirmation beeps.
Reading and executing a Code autotest sequence (Android application on mobile
devices)
Pair the instrument with the mobile device (Smart phones, Tablets). Using PATLink
Android application autotest sequence QR codes or barcodes can be scanned and tests
can be executed remotely.