4.6.3 LCD contrast and backlight
In this menu the contrast and backlight mode of the LCD can be set.
Figure 4.9: LCD contrast menu
Backlight modes:
AUTO The high backlight level is active for 30 seconds after last pressing of any key.
Then the backlight level returns to low level until a key is pressed again.
OFF Backlight level is low.
ON Backlight level is high.
Keys:
TAB
Toggles between setup of contrast and backlight
Sets contrast value or backlight mode
/
Confirms selection and returns to Setup menu.
TEST
Returns to Setup menu without changes.
ESC
Note:
If you press the down () key while starting up the instrument you will automatically
jump to the LCD contrast menu.
While the instrument is connected to mains voltage the backlight is automatically
switched to the HIGH level.
4.6.4 Nominal voltage selection
The DeltaPAT instrument supports testing of 110 V and 230 V portable appliances. For
110 V appliances the substitute leakage current results should be scaled to 110 V.
The appliance nominal voltage can be set in this menu.
Figure 4.10: Language menu
Keys:
Selects the appliance nominal voltage.
/
Confirms selection and returns to Setup menu.
TEST
Returns to Setup menu without changes.
ESC
Note:
The icon is displayed in the Substitute leakage and Substitute leakage-P