Operation Manual

MI 3309 DeltaPAT Automatic test sequences
53
-a Normal polarity test If Active polarity test is set.
The operator must decide by itself if the alternative tests are applicable. Refer to
chapter 1.1 Warnings for more information.
6.3 Selecting the autotest shortcut sequence
Select SHORTCUT MENU in Main menu. The autotest sequence can be selected with
three-digit test code or on base of selected appliances type, class and other parameters.
Figure 6.2: Shortcut menu
The three-digit autotest code can also be selected by using the barcode reader or RFID
reader/writer. In this case connect barcode reader or RFID reader/writer to the instrument
first (RS232 / PS2 connector). Set RS 232 communication port and baud rate to 9600 bps
using Communication function in Setup menu. Select SHORTCUT MENU in Main menu.
A successfully scanned barcode or RFID tag is confirmed by two short confirmation beeps.
A new autotest sequence will be accepted by the instrument.
Figure 6.3: Connection of the barcode reader and RFID reader/writer
Keys:
/
Sets Shortcut code
Sets parameter or value in selected (highlighted) item.
Cancels selection of Shortcut test sequence and returns to Main menu.
ESC
Starts selected test sequence.
TEST
6.4 Carrying out (Simple, Shortcut) test sequences
General meaning of keys during a Simple or Shortcut test sequence:
TAB, /
Sets option.
Sets limit value in selected (highlighted) item.
Cancels test sequence and returns to the top of the test menu without
changes.
ESC
Starts / repeats selected measurement or proceeds to next step.
TEST