Operation Manual
MI 3309 DeltaGT Appendix C – Pre-programmed autotests (UK)
72
Type
Class Fuse
Cord Earth Bond
Limit Out
Insulation
Limit Out
S. Leakage
Limit
Leakage
Limit
T. Leakage
Limit
Code
Heating and
Cooking
I 3 A short 0.10Ω 10 A - - - 0.75 mA - 027
I 6 A short 0.10 10 A - - - 1.00 mA - 028
I 10 A short 0.10 25 A - - - 1.50 mA - 029
I 13 A short 0.10 Ω 25 A - - - 2.25 mA - 030
I 3 A short 0.10 10 A - - 0.75 mA - - 031
I 6 A short 0.10 10 A - - 1.00 mA - - 032
I 10 A short 0.10 25 A - - 1.50 mA - - 033
I 13 A short 0.10 25 A - - 2.25 mA - - 034
II - - - - 2.00 M 500 V - 0.25 mA - 035
II - - - - 2.00 MΩ 500 V - - - 036
Type
Class Fuse
Cord Earth Bond
Limit Out
Insulation
Limit Out
S. Leakage
Limit
Leakage
Limit
T. Leakage
Limit
Code
IT equipment
EN 60950
I - short 0.10 100
mA
1.00 M 500 V 3.5 mA - - 037
I - midd 0.30 100
mA
1.00 M 500 V 3.5 mA - - 038
I - long 0.50 100
mA
1.00 M 500 V 3.5 mA - - 039
IT equipment
EN 60950 –
250V
I - long 0.50 Ω 100
mA
1.00 MΩ 250 V 3.5 mA - - 040
Type
Class Fuse
Cord Earth Bond
Limit Out
Insulation
Limit Out
S. Leakage
Limit
Leakage
Limit
T. Leakage
Limit
Code
OTHER
I 3 A short 0.10 10 A 1.00 M 500 V - 3.50 mA - 041
I 6 A short 0.10 10 A 1.00 M 500 V - 3.50 mA - 042
I 10 A short 0.10 25A 1.00 M 500 V - 3.50 mA - 043
I 13 A short 0.10 Ω 25 A 1.00 MΩ 500 V - 3.50 mA - 044
-
I 3 A short 0.10 10 A 1.00 M 500 V - - 045
I 6 A short 0.10 10 A 1.00 M 500 V - - - 046
I 10 A short 0.10 25 A 1.00 M 500 V - - - 047
I 13 A short 0.10 Ω 25 A 1.00 MΩ 500 V - - - 048
I 3 A midd 0.30 10 A 1.00 M 500 V - 3.50 mA - 049
I 6 A midd 0.30 10 A 1.00 M 500 V - 3.50 mA - 050
I 10 A midd 0.30 25 A 1.00 M 500 V - 3.50 mA - 051
I 13 A midd 0.30 Ω 25 A 1.00 MΩ 500 V - 3.50 mA - 052
I 3 A midd 0.30 10 A 1.00 M 500 V - - - 053
I 6 A midd 0.30 10 A 1.00 M 500 V - - - 054
I 10 A midd 0.30 25 A 1.00 M 500 V - - - 055
I 13 A midd 0.30 Ω 25 A 1.00 MΩ 500 V - - - 056
I 3 A long 0.50 10 A 1.00 M 500 V - 3.50 mA - 057
I 6 A long 0.50 10 A 1.00 M 500 V - 3.50 mA - 058
I 10 A long 0.50 25 A 1.00 M 500 V - 3.50 mA - 059
I 13 A long 0.50 Ω 25 A 1.00 MΩ 500 V - 3.50 mA - 060
I 3 A long 0.50 10 A 1.00 M 500 V - - - 061
I 6 A long 0.50 10 A 1.00 M 500 V - - - 062
I 10 A long 0.50 25 A 1.00 M 500 V - - - 063