Operation Manual

MI 2092 Power Harmonics Analyser Section VII Modem data transfer
59
Notes:
- For GSM system, pay attention to install its antenna at the appropriate place with
good signal condition.
- If modem communication is enabled, it is not passible to transfer data from the
instrument to the PC using RS232 connection. To enable direct RS 232 connection
between the instrument and PC, you should disable modem communication in
Power Link and on the instrument.
3. Modem, ins. and power link configuration
3.1. Power Link configuration
Power Link software should be configured before establishing modem communication.
The following procedure is required:
- Run Power Link application.
- Select Communication Settings menu and enable modem communication (see
the following figure).
- Select GSM or Standard modem for local and standard modem.
- Enter PIN codes for local modem (connected to PC) and target modem (connected
to the instrument) if required.
- Enter the phone number of the target modem (connected to the instrument) the
program will communicate with.
- Set suitable baud rate.
- Save the settings.