Operation Manual
OmegaGTPlus / BetaGTPlus Technical specifications
83
Test duration............. 5 s, 10 s, 30 s, 60 s, 120 s, 180 s
Input current clamp terminals
8.8 Trip-out time of portable RCD
Portable RCD trip-out time readout
Range Resolution Accuracy
0 ms ÷ 1999 ms(½×I
ΔN
)
1 ms
0 ms ÷ 300 ms (I
ΔN
)
1 ms
0 ms ÷ 40 ms (5×I
ΔN
)
1 ms
±3 ms
Test currents (I
ΔN
) ............. 10 mA, 15 mA, 30 mA
Test current multipliers ..... ½×I
ΔN
, I
ΔN
, 5×I
ΔN
Start angle ........................ 0°, 180°, both
Test modes....................... single, autotest
Output............................... PRCD probe connector – test socket
Trip out times according to EN 61008 / EN 61009
½×I
ΔN
I
ΔN
5×I
ΔN
t
Δ
> 300 ms t
Δ
< 300 ms t
Δ
< 40 ms
8.9 Functional test
Apparent power readout
Range Resolution Accuracy
0.00 kVA ÷ 4.00 kVA
0.01 kVA
±(5 % of reading + 3 digits)
Test duration............. 5 s, 10 s, 30 s, 60 s, 120 s, 180 s
Output....................... test socket
8.10 Flash test (MI 3305 – OmegaGTPlus only)
Flash current readout
Range Resolution Accuracy
0.00 - 2.50 mA 0.01 mA
±(5 % of reading + 5 digit)
Test voltage .............. 1500 V AC, 3000 V AC
Output resistance...... 480 kΩ@1500 V, 960 kΩ@3000 V
Limits ........................ 1.00 mA, 1.50 mA, 2.00 mA, 2.25 mA
Timer ........................ 2 s, 3 s, 5 s, 10 s, 30 s, 60 s, 120 s, 180 s
Output....................... Class 1: test socket
Class 2: test socket (L+N) – flash probe connector