Operation Manual
OmegaGTPlus / BetaGTPlus Technical specifications
84
8.11 General data
Rated supply voltage .........................230 V AC (±10 %, 50 or 60 Hz)
Max. power consumption...................150 VA (without tested appliance)
Maximum appliance current...............16 A
Overvoltage category.........................Cat II / 300 V
Protection classification .....................I
Pollution degree.................................2
Degree of protection ..........................IP 50 (closed and locked cover)
Case ..................................................shock proof plastic / portable
Display...............................................240*128 dots graphic matrix display with backlight
Dimensions (w×h×d)..........................33.5 cm × 16.0 cm × 33.5 cm
Weight (with standard accessories)...8.4 kg
Memory..............................................6800 memory locations
RS232 interfaces .............................. 1200 bps ÷ 115200 bps, 1 start bit, 8 data bits,
1 stop bit
RS232 connectors .............................9-pin subminiature type D, female
Label printer connector.......................6-pin DIN connector, female
USB interface ....................................1200 bps ÷ 115200 bps
USB connector...................................type B
Reference conditions
Reference temperature range............5 °C ÷ 35 °C
Reference humidity range..................35 % ÷ 65 % RH
Operation conditions
Working temperature range ...............-10 °C ÷ +50 °C
Maximum relative humidity ................85 % RH (0 °C ÷ 40 °C), non-condensing
Storage conditions
Temperature range............................-10 °C ÷ +60 °C
Maximum relative humidity ................90 % RH (-10 °C ÷ +40 °C)
80 % RH (40 °C ÷ 60 °C)
The error in operating conditions could be at most the error for reference conditions
(specified in the manual for each function) +0.2 % of measured value per °C + 1 digit,
unless otherwise specified in the manual for particular function.
Fuses
Instrument protection .........................2 x T16 A / 250 V, 6.3 × 32 mm
Safety pre-tests
Ì External voltage between L and PE or N and PE (DC and AC)
Ì Excessive leakage between L and PE
Ì Short circuit or too low resistance between L and N
Connectivity (fuse) pre-test
• Appliance not switched on or too high resistance between L and N
Maximum resistance for connectivity pre-test..................................30 kΩ