Autotest organizer view menu
F.2.2 Example of creating a test sequence with autotest organizer
A periodic test of an iron will be performed.
Type: flatiron ABC
Un 230V, 50Hz, 1000VA:
The iron can be classified as followed:
- For a periodic testing, e.g. the NEN 3140 test is relevant.
- The iron can be classified as a Class I DUT with isolated metal part and short
supply cord.
Example of test sequence configuration:
Displayed item Activity
1 Standard: NEN 3140
Information that a test acc. to NEN 3140
(see note) will be set.
Note:
Option on request.
2
DUT class: 1
Selection of DUT safety class:
- Select Class I.
3 Visual test
Information that visual test will be included
in the VDE / Class I procedure.
4 Accessible conductive parts? YES
Question if there is an isolated conductive
part on the DUT:
- Confirm with yes.
5
Cord length (Earth bond)
L: < 0.3 Ω/<=5 m
Selection of Earth bond limit value on base
of known supply cable length:
- Select appropriate length.
6
Insulation test applicable? YES
Question if insulation test is applicable:
- Confirm with yes.
Insulation and substitute leakage
measurements will be included in the test
sequence with this confirmation.
7 Insulation test Classification of DUT: