Operation Manual

MI 3310 / MI 3310A SigmaGT Technical specifications
25
Protection classification
Power supply: ........................... Class I, mains supply
Class II, only battery supply
Pollution degree: ....................... 2
Degree of protection: ................ IP 30 (closed and locked cover)
IP 20 main test socket
Case: ........................................ shock proof plastic / portable
Display: ..................................... 240*128 dots graphic matrix display with backlight
Memory: .................................... 6000 memory locations
Communication interface
RS232 interfaces: ..................... 9600 bps 115200 bps, 1 start bit, 8 data bits, 1 stop
bit
RS232 connectors: ................... 9-pin sub miniature type D, female
USB interface: .......................... 9600 bps 115200 bps
USB connector:......................... type B
Bluetooth communication: ........ 115200 bps
Insulation:
Communication ports to PE: ..... 600 k, 5 %
Dimensions (w×h×d): ................ 31cm × 13cm × 25cm
Weight
(with standard accessories): ..... 5 kg
Reference conditions
Reference temperature range: .. 15 C 35 C
Reference humidity range: ........ 35 % 65 % RH
Operation conditions
Working temperature range: ..... 0 C +40 C
Maximum relative humidity: ...... 85 % RH (0 C 40 C), non-condensing
Storage conditions
Temperature range: .................. -10 C +60 C
Maximum relative humidity: ...... 90 % RH (-10 C +40 C)
80 % RH (40 C 60 C)
Accuracies apply for 1 year in reference conditions. Temperature coefficient outside
these limits is 0.2 % of measured value per
C plus 1 digit, otherwise noted.
Fuses
Test socket protection: .............. 2 x T16 A / H 500 V, 6.3 32 mm