The index box assembly contains a reed 
switch (G) and a corresponding magnet (F). 
The magnet should be positioned so there is 
0.07" - 0.1" clearance between the magnet and 
switch. To adjust this clearance, refer to Fig. 
1-3 on page 9 and do the following: 
Magnet Sensor Adjustment 
The index box assembly contains a reed switch 
(G) and a corresponding magnet (F). The magnet 
should be positioned so there is 0.07”-0.01” 
clearance between the magnet and switch 
(1.78mm-0.25mm). To adjust, refer to Figure 2-2 
and do the following: 
1.  Loosen set screw h. 
2.  Move the magnet until clearance is 
correct. 
3.  Retighten set screw h. 
4.  Verify the clearance is still correct. 
If not, repeat the procedure. 
Figure 2- 3 Base Plate Showing Unit & 
Index Rotation 
UNIT AND INDEX ROTATION 
In general, the label side of the index base 
plate (front) should face the front of the meter.  
This allows the MTEK6000 EFC to also face 
the front of the meter. In certain applications, 
the MTEK6000 EFC and index can be 
installed 180
0
 from the standard position so 
that viewing of the MTEK6000 EFC is 
acceptable. To rotate the unit and index, refer 
to Fig. 2-3 and do the following: 
1.   Remove the 4 bolts at location A. 
2.   Rotate the base plate 180
0
 clockwise so 
that the front label side is now facing the 
rear of the unit. 
3.   Insert the 4 bolts into location B with the 
two lockwashers as shown. Fig. 2-3 
shows the index orientation after the 
rotation is completed. (DO NOT 
OVERTIGHTEN). 
COUNTER MASKING 
NOTE 
When you have changed the input drive 
value, be sure to remove the existing drive 
value label from the window and replace it 
with a new label that states the current input 
drive value. For your convenience, 
Metretek, Inc. supplies extra labels with the 
MTEK6000 EFC. 