User`s manual
 MTEK6000 SERIES USER'S MANUAL 
January 2002 B-1 
APPENDIX B: CALCULATIONS 
AGA-7 Volume Calculations 
The MTEK6000 EFC performs volume 
calculations based on the Ideal Gas Law.  
Boyle’s Law is used for pressure and 
Charles’s Law for temperature. These laws 
state that the volume of any definite weight of 
a perfect gas varies inversely with change in 
absolute pressure and directly with change in 
absolute temperature. The unit can perform 
such calculations for turbine, rotary, and 
diaphragm displacement meters. 
Vc = Vu x (Pm + Pa) x Tb + 459.67 x (Fpv)2 
 Pb Tm + 459.67 
Where: 
 Vc  = Volume corrected to base conditions 
 Vu  = Uncorrected line volume 
 Pm  = Measured line pressure (psig) 
 Pa = Atmospheric pressure 
 Pb  = Base pressure 
 Tb  = Base temperature (
0
F) 
 Tm = Measured line temperature (
0
F) 
 Fpv = Supercompressibility factor 
The unit makes continuous correction for the 
specified gas composition based on actual 
sensed pressure and temperature. 
NOTE 
All of the AGA factors can be based on either 
flowing or constant values. 
The supercompressibility factor can be 
calculated from either NX-19 or AGA-8 
Gross Methods 1 and 2 reports and applied to 
the volume equation. 
NX19 Supercompressibility Report 
The EFC is configured with values for 
specific gravity, mol percent of N2 and CO2. 
AGA-8
 Supercompressibility Gross Method 1  
The EFC is configured with values for BTU 
content, specific gravity and mol percent of 
CO2. 
AGA-8 Supercompressibility Gross Method 2  
The EFC is configured with values for 
specific gravity and mol percent of N2 and 
CO2. 