User`s manual
 MTEK6000 SERIES USER'S MANUAL 
January 2002  1 - 1 
CHAPTER 1: OVERVIEW 
NOTE: The MTEK6000 is similar in 
many respects to the Metretek AE6000 
but there are also differences. The 
information in this manual applies only to 
the MTEK6000. 
The MTEK6000 series products are low-
cost microprocessor-controlled, electronic 
devices for measuring gas flow and volumes 
or monitoring pressure and temperature for a 
system. With integral pressure and 
temperature transducers, the MTEK6000 is 
designed for accuracy, reliability, and ease 
of maintenance. It can mount directly on a 
meter's index plate, on a wall or pipe. 
Low-power CMOS design and sophisticated 
power conservation circuitry allow the 
MTEK6000 to operate one to two years on 
battery power. 
Two pulse inputs, two status inputs, two 
pulse outputs, two external analog inputs  
(4-20 mA or 1-5V) and a tamper input are 
standard. A large 13-digit LCD display, 
with a magnetic scroll switch located on the 
enclosure exterior, permits data viewing 
without opening the enclosure. Station 
parameter display and alarm display can be 
performed with only external device. The 
standard internal 2400/1200/300 baud 
modem provides remote configuration, 
calibration, and retrieval of data. 
The operator can also use an industry-
standard portable computer running 
Metretek software to configure parameters.   
See Chapter 5 for information on these 
packages. The MTEK6000 calculates 
corrected volume using AGA-7, AGA-3, 
AGA-5 and NX-9 or AGA-8 reports. 
Optional equipment includes an external 
keypad and display for configuration and 
calibration, analog output modules, two 
additional pulse outputs, serial port modules, 
and various security options. 
The MTEK6000 product line consists of six 
models that cover a wide range of 
applications. 
•  The MTEK6000 EFCV provides a live 
pressure and temperature reading in 
volume corrections for Positive 
Displacement meters (turbine, etc.) 
•  The MTEK6000 EFCP provides a live 
pressure and a fixed temperature reading 
in volume corrections for Positive 
Displacement meters (turbine, etc.) 
•  The MTEK6000 EFM provides a live 
pressure and temperature reading in 
volume corrections for Orifice meters. 
•  The MTEK6000 EPR provides a live 
pressure reading for monitoring systems. 
•  The MTEK6000 ETR provides a live 
temperature reading for monitoring 
systems. 
•  The MTEK6000 EPTR provides a live 
pressure and temperature reading for 
monitoring systems. 
HAZARDOUS LOCATIONS 
The MTEK6000 is listed by Underwriter’s 
Laboratories to bear the UL/C-UL mark (US 
& Canadian Listing) for use in hazardous 
locations. 
The intrinsically safe version can be 
installed in a Class I, Division 1, Group D 
hazardous location when connected through 
the intrinsic safety barriers as listed in 
control drawing 401061. A copy of this 
drawing is shown in appendix E. 
The non-incendive version can be installed 
in a Class I, Division II, Group D hazardous 
location when installed in accordance with 
control drawing 401060. 
This drawing is also listed in Appendix E. 