TEMPERATURE SWITCH
Commercial name TEMP-SENSOR-M14-95C-NC TEMP-SENSOR-9/16-95C-NC
Part number A22073S A22572K
Compatibility Electronic transmission management
Fonction Measure the temperature of the hydraulic circuit
Features
Threshold of temperature 95°C ± 3 [203°F± 37.4]
Hysteresis < 20°C [68°F]
Type of contact switch opens with increasing temperature
Max. voltage 30 Volt
Max. current Ohmic load 16A and inductive load 10A
Using temperature range -40 to +130°C [-40 to +266°F]
Max. pressure 100 bar [1 450 PSI]
Ingress protection IP67
Housing material CuZn38Pb2