Operating instructions

10/04/2015 57
POCLAIN HYDRAULICS Electronic mobile
Electronic control unitsElectronic componentsConnectorsCables Displays
Layout
Installation
Fixing on support :
To fix the pedals, provide a plate at least 4 mm [0.16"] thick.
Ref. Quantity Class
N.m [lb.ft] ± 10 %
(as
per standard DIN 912)
M 6 2 8.8 10 [7.37]
Electrical wiring
2 cables provided with the pedal :
Sensor wire
ID
Function
1cable with Weather Pack connector
A Ground
BSignal
CSupply
1 cable with Metri Pack connector
A Supply
BSignal
C Ground
At rest, the signal tension is min.
For connector wiring, please refer to the cable table and to the general wiring diagram in the installation documentation for
your transmission system.
When wiring, check that the wire can neither be cut off, nor torn off when the machine is
working or moving.
Cable with MetriPack connector Cable with WeatherPack connector
1