Operation Manual
M
X670 / MX675 31
5
TECHNICAL SPECIFICATIONS
5.1 General
The tolerances assigned to the values, or declared limits,
constitute only the values guaranteed by the manufacturer.
Values without a tolerance are for information only.
The symbol
is displayed when the input signals exceed
the limit values possible in each measurement range.
The symbol - is displayed in °C/°F measurement when
there is no input signal (open circuit).
5.2 Characteristics
Accuracy is to within ± [% of the reading (L) + number of
counts (cts)] in the reference conditions indicated in the
appendix.
5.2.1 DC voltage
Range
Measuring range
Resolution
Accuracy
1000 V
0.0 to 999.9 V 0.1 V
1% ± 2 cts
1400 V
1000 to 1400 V
1 V
1% ± 2 cts
Input resistance: 1 MΩ
Overload indication: 1400 VDC
5.2.2 AC voltage
Range
Measuring range
Resolution
Accuracy
1000 V
0.0 to 999.9 V 0.1 V
1.0% ± 5 cts (50 – 60Hz)
1.2% ± 5 cts (60 -500Hz)
2.5%± 5 cts (500Hz – 3kHz)
Input resistance: 1 MΩ
Overload indication: 1000 Vrms
5.2.3 DC current (MX675 only)
Range Measuring range Resolution Accuracy
100 A 0.00 to 99.99 A 0.01 A
1.2% ± 5 cts
1000 A 100.0 to 999.9 A 0.1 A
2.5% ± 5 cts
1400 A 1000 to 1400 A 1 A
2.5% ± 5 cts
Overload indication: 1400 ADC
5.2.4 AC current
Range
Measuring range
Resolution
Accuracy
100 A 0.00 to 99.99 A
0.01 A
1000 A
100 to 1000 A 0.1 A
1.5% ± 5 cts (50 -60Hz)
2.0% ± 5 cts (60 -500Hz)
4.5% ± 5 cts (500Hz –
3kHz)
Overload indication: 1000 A Rms
5.2.5 Resistance (Ω
ΩΩ
Ω)
Range Measuring range Resolution
Accuracy
1000 Ω 0.0 to 999.9 Ω 0,1 Ω
10000 Ω 1000 to 9999 Ω 1 Ω
1% ± 3cts
3.3 VDC (Vmax)
Protection: 1 000 V rms
5.2.6 Continuity