Master Hub Configuration & Console Management 69
Network Configuration
There are several ways or Network Interfaces that you can use to config-
ure the hub. You must set up the hub using Local Console management to
enable the other management capabilities:
Mini Console (see Chapter 3)
Local Console/Remote Telnet
Web-Based Management
SNMP Management
The Network Configuration Menu allows setting up Ethernet and SLIP
connections to the hub. Network Interface <1> is used to configure
Ethernet connections and Network Interface <2> is used to configure
SLIP connections.
Local Console/Remote Telnet-Ethernet
An Ethernet connection allows you to monitor and configure the hub with
a Local Console via Telnet Session, a Web browser or SNMP
management. You need to configure the IP Address and Subnet Mask to
work with your LAN settings before you can make an Ethernet
connection.
In-Band Ethernet Configuration Menu