User guide

12 Installation Guide
Connect to the Network
A total of three connections must be made on the front panel when
connecting the “redundant twister” media converter to the network.
Connect to the MAIN port.
Each “redundant twister” provides one RJ-45 jack for 10BASE-T
connections that supports a maximum segment length of 100m Category 3
or 5 twisted-pair; or one RJ-45 jack for 100BASE-TX connections that
support a maximum segment length of 100m of Category 5 twisted-pair.
Connect to the PRIMARY port.
Connect to the SECONDARY port.
The “redundant twister” 2731-11 (100Mbps) and 2711-11 (10Mbps)
each provide two sets of RJ-45 connectors that support a maximum
cable length of 100m.
The “redundant twister” 2731-13 and 2731-15 each provide two sets of
100BASE-FX multimode SC/ST connectors that each support a
maximum cable length of 2km.
The “redundant twister” 2731-14, 2731-17 and 2731-1J provide two
sets of 100BASE-FX singlemode SC connectors. The 2731-14 supports
a maximum cable length of 15km, the 2731-17 supports a maximum
segment length of 40km, and the 2731-1J supports a maximum length
of 100km.
IMPORTANT: 100Mbps RJ-45 ports are wired straight through. Before
making the proper twisted-pair connection, you must verify the port
configuration of the connected device. This does not apply to 10Mbps
models.
4
External Crossover Function
TD+
TD-
RD+
RD-
redundant twister 2731
TP Port Configuration
Device with Straight Through
TP Port Configuration
redundant twister 2731
TP Port Configuration
Typical Hub
TP Port Configuration
TD+
TD-
RD+
RD-
Embedded Crossover Function
MDIXMDI
TD+
TD-
RD+
RD-
1
2
3
6
1
2
3
6
1
2
3
6
1
2
3
6
TD+
TD-
RD+
RD-