Radiance R1000 Premise Service Platform 9
Apply Power to the Platform
Depending on the model, power connections are located on the front or
rear of the R1000. When lit, the power (PWR) LEDs indicate that their
corresponding power supplies are connected to an active power source
and providing power to the platform’s backplane. Because the power
supplies are load-sharing, both PWR LEDs are lit simultaneously.
DC Power Supply Connections
IMPORTANT: • For installation in a restricted access location only.
• A readily accessible disconnect device must be
incorporated in the building installation wiring.
• Turn off the DC voltage source before beginning.
• Connect the wire leads to the R1000 before applying
power.
For DC connections, follow these guidelines:
Remove the terminal block safety cover.
Connect the wire leads from the voltage source to the appropriate
terminal and tighten the screws. If your unit has two DC connections,
make sure each power supply is connected to a separate power
source.
Replace the terminal block safety cover.
•Verify proper connection and operation using the PWR LED.
IMPORTANT: The terminal block safety cover must be installed when
power is present to prevent burn or energy hazards.
Caution: The center terminal connector provides grounding for the
R1000 and should be maintained. Particular attention should
be given to power supply connections other than direct
connections to the branch circuit (e.g. use of power strips).
5