Troubleshooting guide
Copyright © 4/20/2006 Travis Industries, Inc.
Configuring the Control Board
Overview
The new AVR control board is the next generation control board that
is compatible with all pellet stoves and inserts, large and small
manufactured from 1997 to today. Circuitry on the board allows it to
be programmed for either the large or small pellet heaters (these heaters
use different voltage settings). See ““ for details. It also includes a
diagnostic feature that allows a service person to diagnose a fault
without having to inspect the wiring or components. The indicator
lights on the control board will display a fault code after a fault has
been detected. This allows the service person to determine which
component caused the fault. See “Diagnostic Codes” for details. NOTE:
the new wiring harness (250-00017) is required to utilize this feature.
Configuring for Large or Small Heaters
The control board is initially configured for the large heaters (Astoria
and Yankee models). To change the configuration the control board
must be in the off position plugged into a cold stove, (no lights or
running components) with the jumper molex removed (see the illustration
below). In this condition press and hold the manual auger button down
and press both fan up and fan down arrow keys at the same time. All
heat output lights will flash. One flash denotes the large pellet heater
configuration. Two flashes denote the small pellet heater configuration
(Newport and Pioneer models). Repeat pressing the keys until the correct
configuration is obtained.
1