Troubleshooting guide
Copyright © 4/20/2006 Travis Industries, Inc.
Troubleshooting Pellet
Appliances
• Keep the operation sequence in mind.
• Ask what should be working in
• each mode and what should not.
• Before troubleshooting any pellet
• •
•
appliance always UNPLUG and
• re-plug THE APPLIANCE to reset the
• control board, (If the appliance was •
turned off before it finished the cool •
down mode it will start there instead •
of the start-up mode).
• Run through the modes and observe
• what is working or not working.
• Begin with what is not working before you move to the
• next mode.
• Each time the pellet system is turned on it runs a quick self-
• •
•
diagnosis, (you will see the fault light come on and then go off).
• If, during this diagnosis, it senses any problem with the convection
• blower or circuit, the exhaust blower will immediately come on,
• even through the ON/OFF switch is off.
• This automatically tells you there is a convection circuit problem
• that must be corrected.
Troubleshooting
Pellet Appliances
• Mode Sequence
• Ask What?
• Unplug To Reset
• Board
• Move Through
•
•
Modes of • • • • •
•
Operation
• Self Diagnosis