Troubleshooting guide

Copyright © 4/20/2006 Travis Industries, Inc.
Troubleshooting Pellet
Appliances
• Keep the operation sequence in mind.
Ask what should be working in
each mode and what should not.
• Before troubleshooting any pellet
• •
appliance always UNPLUG and
re-plug THE APPLIANCE to reset the
control board, (If the appliance was
turned off before it finished the cool
down mode it will start there instead
of the start-up mode).
• Run through the modes and observe
what is working or not working.
• Begin with what is not working before you move to the
next mode.
• Each time the pellet system is turned on it runs a quick self-
• •
diagnosis, (you will see the fault light come on and then go off).
• If, during this diagnosis, it senses any problem with the convection
blower or circuit, the exhaust blower will immediately come on,
even through the ON/OFF switch is off.
• This automatically tells you there is a convection circuit problem
that must be corrected.
Troubleshooting
Pellet Appliances
• Mode Sequence
Ask What?
• Unplug To Reset
Board
• Move Through
Modes of • • • • •
Operation
• Self Diagnosis
14