Troubleshooting guide
Copyright © 4/20/2006 Travis Industries, Inc.
Pellet Appliance Works on Manual But
Not on Automatic (Thermostat)
CHECK
POSSIBLE CAUSE
CORRECTIVE ACTION
Control
Board
Thermostat
Control
Board
• Switch not in auto
• position
• Thermostat wires not
• connected
• Move to auto
• position
• Connect to control •
• board
• Improper setting
• Improper location
• picking up heat from
• some other device
• Defective
• thermostat
• Defective
• wires
• Set to proper setting
• Remove heat
• source or move • • •
• thermostat
• Check and replace •
• as necessary
• Check and replace •
• as necessary
• If all of the above is
• good the control • •
• board is defective
• Replace control • • •
• board