Troubleshooting guide

Copyright © 4/20/2006 Travis Industries, Inc.
Pellet Appliance Works on Manual But
Not on Automatic (Thermostat)
CHECK
POSSIBLE CAUSE
CORRECTIVE ACTION
Control
Board
Thermostat
Control
Board
• Switch not in auto
position
• Thermostat wires not
connected
• Move to auto
position
• Connect to control
board
• Improper setting
• Improper location
picking up heat from
some other device
• Defective
thermostat
• Defective
wires
• Set to proper setting
• Remove heat
source or move • • •
thermostat
• Check and replace
as necessary
• Check and replace
as necessary
• If all of the above is
good the control • •
board is defective
• Replace control • • •
board
1