mlpn 2348 cover.qxd 9/21/2004 2:57 PM Page 1 METROLOGIC INSTRUMENTS, INC.
LOCATIONS CORPORATE HEADQUARTERS NORTH AMERICA EUROPEAN, MIDDLE EAST & AFRICAN HEADQUARTERS USA, NEW JERSEY Metrologic Instruments, Inc. Tel: 1-800-ID-METRO Fax: 856-228-6673 Email: info@metrologic.com GERMANY, MUNICH Metrologic Instruments GmbH Tel: 49-89-89019-0 Fax: 49-89-89019-200 Email: info@europe.metrologic.com SOUTH AMERICA, BRAZIL SÃO PAULO Metrologic do Brasil Ltda. Tel: 55-11-5182-8226 Fax: 55-11-5182-8315 Email: info@br.metrologic.
TABLE OF CONTENTS Introduction .......................................................................................................... 1 Scanner and Accessories .................................................................................... 1 Scanner Installation.............................................................................................. 2 Scanner Configuration to the Host System .......................................................... 3 Parts of the Scanner .....................
INTRODUCTION The IS4220 ScanGlove® is a fully automatic single-line laser barcode scanner. It is designed to be used as a “hands-free” wearable scanner or a stationary desktop scanner. Every ScanGlove is equipped with ScanQuest®, a patented activation technology that allows the scanner to read bar codes automatically as the operator presents the bar code to the scanner.
SCANNER INSTALLATION 1. Turn off power to the host system. 2. Connect the communication cable to the proper port on the host device. 3. Turn on power to the host system. When the IS4220 first receives power, the red LED will flash, the green LED will flash, and then the scanner will beep once. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.
SCANNER CONFIGURATION TO THE HOST SYSTEM The IS4220 is shipped from the factory pre-programmed to a set of default parameters. It may be necessary to change the default parameters to match the host system’s requirements or to enable additional scanner functions. For a list of possible parameter settings, refer to the Default Settings section of this guide. Important notes for the -07 and -08, IS4220 USB Interfaces.
PARTS OF THE SCANNER Figure 1. Scanner Parts Item No. Description Green LED When a bar code is read successfully the green LED will flash. Red LED When the red LED is illuminated, the laser is on. Red Output Window (Laser Aperture) Infrared Sensor (IR) If a specified time has elapsed without any scanning, the unit will enter a “standby” mode. To reactivate the unit, place an object in front of the IR sensor. The red LED will turn on when the scanner is ready to scan.
VISUAL INDICATORS There is a red and a green LED located on the top of the scanner. When the scanner is on, the flashing or constant illumination of the LEDs indicates the status of the current scan and the scanner. No Red LED Illumination of the LEDs will not occur if the scanner has remained dormant for a specified time and the scanner is not receiving power from the host. To reactivate the unit, direct the output window up then down toward the object.
SIGNAUX OPTIQUES Sur la partie supérieure du scanner se trouvent une diode LED rouge et une diode LED verte. Quand le scanner est sous tension, les diodes rouge et verte clignotantes ou allumées vous informent sur l'état de palpage et de scanner. Ni la diode rouge, ni la diode verte n'est allumée Il existe deux raisons possibles pour que les diodes ne s'allu-ment pas. Si le scanner ne reçoit pas d'énergie de l'ordinateur PC, les diodes ne s'allument pas.
OPTISCHE ANZEIGEN Auf der Oberseite des Scanners befinden sich eine rote und eine grüne Leuchtdiodenanzeige. Ist der Scanner eingeschaltet, so geben Ihnen die blinkenden oder feststehenden Leuchtdiodenanzeigen Aufschluß über den Abtast und Scannerstatus. Weder rote oder noch grüne Leuchtanzeige Es gibt zwei mögliche Gründe, weshalb die Leuchtdiodenan zeigen nicht aufleuchten. Bekommt der Scanner keine Energie vom PC, leuchten die Leuchtdiodenanzeigen nicht auf.
SEGNALI OTTICI Sulla parte superiore dello scanner si trovano due diodi luminosi: uno rosso e uno verde. Quando lo scanner è inserito, i diodi luminosi, che possono o essere accesi in continuazione o lampeggiare, Vi informano sullo stato della scansione e dell’apparecchio. Né il diodo luminoso rosso né quello verde sono accesi Vi sono due possibili cause se i diodi luminosi non sono accesi. Se lo scanner non viene alimentato dal PC i diodi luminosi non sono accesi.
AUDIBLE INDICATORS The scanner provides sounds to signal certain conditions. To change the volume (four settings are available) or turn the beeper off, refer to Beeper Tones in the Programming Guide. One Beep When the scanner first receives power, the red LED will flash, followed by the green LED, and then the scanner will beep once. After the scanner performs this start-up sequence, the scanner is ready to scan.
LABELS Each IS4220 has a serial number label and a laser class label on the bottom of the unit. These labels provide important information like; date and location of manufacture, model number, serial number, caution statements and laser class. There is also text molded into the top of the case near the window that says, “AVOID EXPOSURE - laser light emitted from this aperture”. The following Figure shows examples of these labels*. Figure 2. Caution and Serial Number Labels* * Labels not shown to scale.
INFRARED (IR) OBJECT SENSOR An infrared (IR) device located behind the window initiates the scanning process. The IR sensor is active as long as power is applied to the unit. When the IR sensor detects an object, the green LED will flash. When the laser decodes a bar code, the scanner transmits the data to the host system and emits a beep to show that decoding is complete. The IR sensor range can be programmed for two ranges.
Scan Field The depth of field for the scanner is 12.7 mm to 203 mm (.5" to 8") from the face of the output window for .33 (13 mil) Bar Codes. Figure 3. Scan Field for .33 (13 mil) Bar Codes Specifications subject to change without notice.
SPECIFICATIONS IS4220 SPECIFICATIONS OPERATIONAL Light Source: 650 nm VLD Depth of Field: 12.7 mm to 203 mm (.5" to 8") for .33 (13 mil) bar code Width of Scan Field: 28.6 mm (1.125”) @ face; 102 mm (4”) @ 76.2 mm (3”) Scan Speed: Scan Pattern: Min Bar Width: 52 scans lines per second Single scan line 0.173 mm (6.
DEFAULT SETTINGS Many functions of the scanner can be "programmed", that is enabled or disabled. The scanner is shipped from the factory programmed to a set of default conditions. All factory default parameters have an asterisk ( * ) in the default column of the charts on the following pages . If an asterisk is not in the default column then the setting is off or disabled by default. Every interface does not support every parameter.
DEFAULT SETTINGS PARAMETER DEFAULT RS232 LIGHT PEN KEYBOARD WEDGE USB ACK/NAK XON/XOFF * No Intercharacter Delay 1 Millisecond Intercharacter Delay 5 Millisecond Intercharacter Delay 10 Millisecond Intercharacter Delay 25 Millisecond Intercharacter Delay 100 Millisecond Intercharacter Delay DTR Input DTR Scan Disable “DE” Disable Command LRC Calc+ Transmit RS232 Start LRC on first RS232 Byte Start LRC on Second RS232 Byte * Carriage Return * Line Feed * STX Prefix ETX Suffix Tab Prefix Tab Suf
DEFAULT SETTINGS PARAMETER DEFAULT Hong Kong Matrix 2 of 5 Airline 2 of 5 Minimum 1 Character Code Length Minimum 3 Character Code Length * Minimum 6 Character Code Length Set Minimum Character Length Set Character Lock Length Transmit UPC-A Number Sys * UPC-A Check Digit Transmit * Convert UPC-A to EAN-13 Expand UPC-E UPC-E Check Digit Transmit UPC-E Leading 0 Transmit EAN-8 Check Digit Transmit * EAN-13 Check Digit Transmit Convert EAN-8 to EAN-13 “$” Prefix ID for UPC/EAN 2 Digit Supps (Scan) 5
DEFAULT SETTINGS PARAMETER DEFAULT RS232 LIGHT PEN KEYBOARD WEDGE USB ]C1 Transmit Coupon C128 Coupon 128 Group Separator Italian Pharmaceutial Codabar Start and Stop Class ITF Minimum Symbol Length Test Matrix 2 of 5 Check Digit Hong Kong Matrix 2 of 5 MSI - Plessey Test of Check Digit * Enable MSI - Plessey Mod 10 Check Digit Enable MSI - Plessey Mod 10/10 Check Digit Transmit MSI - Plessey Check Digit * UK Plessey UK Plessey Check Digit UK Plessey Special Format A to X conversion (UK) Scan Coun
DEFAULT SETTINGS PARAMETER DEFAULT RTS Counter Toggle Beep on BEL RS232 Bancorner Mode FedEX parsing Retransmit of Same Code 1st Programmable Prefix ID 2nd Programmable Prefix ID 1st Programmable Suffix ID 2nd Programmable Suffix ID Clear all Programmable Prefixes and Suffixes SNI Beetle Mode ATKeyboard * Type XT Keyboard Type PS2 Keyboard USA Keyboard * Belgium Keyboard France Keyboard Germany Keyboard Spain Keyboard Italy Keyboard UK Keyboard IBM KDB4700 Financial Keyboard Alt Mode Auto Detection or
TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 20. SYMPTOMS POSSIBLE CAUSE(S) SOLUTION No Power is being supplied to the scanner Make sure the cable is plugged into the host. Check the host system’s power cable, the outlet and power strip. No LEDs, beep and there is no visible laser No power is being supplied from the USB port.
LIMITED W ARRANTY The IS4220 ScanGlove® scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The IS4220 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all IS4220 scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and local laws, regulations and ordinances pertaining to their production and labeling.
NOTICES Notice This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
NOTICES European Standard Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Funkstöreigenschaften nach EN 55022:1998 Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen; in diesem fall kann vom Betrieber verlangt werden, angemessene Maßnahmen durchführen. Standard Europeo Attenzione Questo e’ un prodotto di classe A.
PATENTS This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No.
INDEX A application .....................................1 audible.......................................5–9 autodiscriminates ........................13 B bar code ..............4, 5–9, 10, 11, 19 beep ........................5–9, 13, 14, 19 C cable....................................1, 4, 13 caution...................................10, 21 CDRH ....................................10, 13 communication ......1, 4, 5–9, 14–18 compliance ..................................20 contrast ..........................
INDEX R T razzberry tone .........................9, 14 red LED .................................4, 5–9 repair ...........................................20 rights ...........................................23 RMA ............................................20 roll, pitch, yaw..............................13 RS232 .............................13, 14–18 temperature ................................ 13 termination .................................. 13 Test.............................................
NOTES
November 2004 Printed in the USA 00 - 02348C